Title: Structural behavior checks prior performing nonlinear dynamic analysis
Authors: Pozo, Sebastián
Astudillo, Bryam
Flores Solano, Francisco Xavier
Charney, Finley
Keywords: Engineering geology
Nonlinear analysis
Modal analysis
Graphical user interfaces
Geophysics
Earthquake engineering
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.1.3 Ingeniería en Construcción
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.1 Ingeniería Civil
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0732 - Construcción e Ingeniería Civil
metadata.dc.ucuenca.areaconocimientounescoespecifico: 073 - Arquitectura y Construcción
Issue Date: 2018
metadata.dc.ucuenca.volumen: Volume 3
metadata.dc.source: 11th National Conference on Earthquake Engineering 2018, NCEE 2018 Proceedings
Publisher: Earthquake Engineering Research Institute
metadata.dc.description.city: 
Los Angeles
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
Students, researchers, and practicing engineers regularly use mathematical models to evaluate the seismic behavior of structures. Advances in the capacity of computer storage capacity and processing speed have allowed these models to be more complex in terms of model extent and analytical features. As a result, evaluation of structures using nonlinear dynamic analyses is more common and even required under certain circumstances. However, one of the possible consequences of having the technology to model complicated structures and behavior is that errors can be committed in the process. Moreover, there is a tendency to perform the most complicated response evaluation once the model has been completed. Thus, little or no understanding of the structure's behavior is acquired, which could lead to invalid results and could waste a considerable amount of time. The probability of having errors in an analysis is increased where the analysis software does not have a graphical user interface, as is the case with OpenSees. Therefore, in this study, a variety of validation tools and checks that can provide an understanding of behavior and confidence in the computed results are presented. While the procedure is generic (applies to all structures), it is demonstrated by example analysis of a 4-story steel system. Analysis is performed in three dimensions in OpenSees. The validation procedure, presented as a checklist, includes: modal analysis, free vibration analysis, nonlinear static pushover analysis, and nonlinear dynamic analysis. All analyses are performed with and without second order effects, and with and without inherent damping. The conclusion from this study is that the proposed validation tools give the researcher or the structural engineer the confidence required to perform more complicated analyses, and to trust the obtained results. © NCEE 2018.All rights reserved.
Description: 
Students, researchers, and practicing engineers regularly use mathematical models to evaluate the seismic behavior of structures. Advances in the capacity of computer storage capacity and processing speed have allowed these models to be more complex in terms of model extent and analytical features. As a result, evaluation of structures using nonlinear dynamic analyses is more common and even required under certain circumstances. However, one of the possible consequences of having the technology to model complicated structures and behavior is that errors can be committed in the process. Moreover, there is a tendency to perform the most complicated response evaluation once the model has been completed. Thus, little or no understanding of the structure's behavior is acquired, which could lead to invalid results and could waste a considerable amount of time. The probability of having errors in an analysis is increased where the analysis software does not have a graphical user interface, as is the case with OpenSees. Therefore, in this study, a variety of validation tools and checks that can provide an understanding of behavior and confidence in the computed results are presented. While the procedure is generic (applies to all structures), it is demonstrated by example analysis of a 4-story steel system. Analysis is performed in three dimensions in OpenSees. The validation procedure, presented as a checklist, includes: modal analysis, free vibration analysis, nonlinear static pushover analysis, and nonlinear dynamic analysis. All analyses are performed with and without second order effects, and with and without inherent damping. The conclusion from this study is that the proposed validation tools give the researcher or the structural engineer the confidence required to perform more complicated analyses, and to trust the obtained results. © NCEE 2018.All rights reserved.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/34892
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85085613914&partnerID=40&md5=cebb4094774ece69746c3c48c669c74d
metadata.dc.ucuenca.urifuente: https://11ncee.org/images/11NCEE-Program-ONLINE.pdf
ISBN: 978-151087325-4
ISSN: 0000-0000
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument7.95 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00