Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/34511
Title: On the design of silicon Mach-Zehnder interferometers for the C-band
Authors: Sanchis Kilders, Pablo
Gutierrez Campo, Ana
Larrea Luzuriaga, Roberto Alejandro
Keywords: Optical waveguides
Optical interferometry
Optical device fabrication
Optical sensors
Indexes
Interferometers
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.11.2 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.11 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0711 - Ingeniería y Procesos Químicos
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2019
metadata.dc.ucuenca.embargoend: 15-Jun-2050
metadata.dc.ucuenca.volumen: Volumen 0, número 0
metadata.dc.source: 2019 IEEE Fourth Ecuador Technical Chapters Meeting (ETCM)
metadata.dc.identifier.doi: 10.1109/ETCM48019.2019.9014907
Publisher: Institute of Electrical and Electronics Engineers Inc.
metadata.dc.description.city: 
Guayaquil
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
A silicon Mach-Zehnder interferometer is designed, fabricated and experimentally demonstrated for the C-band. Several interferometers were designed with different free spectral ranges. The influence of the waveguide width was carefully analyzed with respect to the performance of the interferometer and a study about the deviation of the design parameters of the waveguide was made.
Description: 
A silicon Mach-Zehnder interferometer is designed, fabricated and experimentally demonstrated for the C-band. Several interferometers were designed with different free spectral ranges. The influence of the waveguide width was carefully analyzed with respect to the performance of the interferometer and a study about the deviation of the design parameters of the waveguide was made.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/34511
https://ieeexplore.ieee.org/document/9014907
metadata.dc.ucuenca.urifuente: https://ieeexplore.ieee.org/xpl/conhome/8999368/proceeding?pageNumber=2
ISBN: 978-172813764-3
ISSN: 0000-0000
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf
  Until 2050-06-15
289.61 kBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00