Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/33182
Título : Accuracy of connected confidence left ventricle segmentation in 3-D multi-slice computerized tomography images
Autor: Medina, Rubén
Bautista Llivisaca, Mateo Sebastian
Morocho Zurita, Carlos Villie
Palabras clave : Connected confidence
Left ventricle segmentation
Multi-slice computerized tomography
Software platform
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.11.2 Otras Ingenierias y Tecnologías
Área de conocimiento FRASCATI específico: 2.11 Otras Ingenierias y Tecnologías
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0914 - Tecnologías de Diagnóstico y Tratamiento Médico
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2018
Fecha de fin de embargo: 30-dic-2050
Volumen: volumen 2017-January
Fuente: Ecuador Technical Chapters Meeting (ETCM), IEEE
metadata.dc.identifier.doi: 10.1109/ETCM.2017.8247499
Editor: Institute of Electrical and Electronics Engineers Inc.
Ciudad: 
Salinas
Tipo: ARTÍCULO DE CONFERENCIA
Abstract: 
Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
Resumen : 
Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
URI : https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85045738426&origin=inward
URI Fuente: https://ieeexplore.ieee.org/xpl/conhome/8232983/proceeding
ISBN : 978-153863894-1
ISSN : 0000-0000
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdf
  Until 2050-12-30
document407.7 kBAdobe PDFVisualizar/Abrir     Solicitar una copia


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00