Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/33182
Title: Accuracy of connected confidence left ventricle segmentation in 3-D multi-slice computerized tomography images
Authors: Medina, Rubén
Bautista Llivisaca, Mateo Sebastian
Morocho Zurita, Carlos Villie
Keywords: Connected confidence
Left ventricle segmentation
Multi-slice computerized tomography
Software platform
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.11.2 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.11 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientounescoamplio: 09 - Salud y Bienestar
metadata.dc.ucuenca.areaconocimientounescodetallado: 0914 - Tecnologías de Diagnóstico y Tratamiento Médico
metadata.dc.ucuenca.areaconocimientounescoespecifico: 091 - Salud
Issue Date: 2018
metadata.dc.ucuenca.embargoend: 30-Dec-2050
metadata.dc.ucuenca.volumen: volumen 2017-January
metadata.dc.source: Ecuador Technical Chapters Meeting (ETCM), IEEE
metadata.dc.identifier.doi: 10.1109/ETCM.2017.8247499
Publisher: Institute of Electrical and Electronics Engineers Inc.
metadata.dc.description.city: 
Salinas
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
Description: 
Cardiovascular diseases are the main cause of death in the World. This fact has motivated different actions for prevention, diagnosis and monitoring of cardiovascular diseases. In this work, the accuracy of a connected confidence left ventricle segmentation method is performed. This task is accomplished using a software platform for left ventricle segmentation of 3-D cardiac Multi-Slice Computerized Tomography (MSCT) images that is also described. The software platform has as a goal performing research about efficient methods for cardiac image segmentation and quantification. The accuracy assessment of the segmentation method is performed by comparing the estimated segmentation with respect to segmentations manually traced by cardiologists. Results show that the segmentation method provides Dice Similarity coefficients higher than 0.90 with low computational cost. The obtained segmentation is able to include within the left ventricular lumen the papillary trabeculae muscles, enabling further accurate estimation of the left ventricular mass.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85045738426&origin=inward
metadata.dc.ucuenca.urifuente: https://ieeexplore.ieee.org/xpl/conhome/8232983/proceeding
ISBN: 978-153863894-1
ISSN: 0000-0000
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdf
  Until 2050-12-30
document407.7 kBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00