Title: Fixed bed column modeling of lead(II) and cadmium(II) ions biosorption on sugarcane bagasse
Authors: Vera Cabezas, Luisa Mayra
Bermejo Campos, Daniel Francisco
Uguña Rosas, Maria Fernanda
Garcia Alvear, Nancy Beatriz
Flores Zamora, Marittza Eleanor
González, Enrique
metadata.dc.ucuenca.correspondencia: González, Enrique, eglezc@ull.es
Keywords: Biosorption In Columns
Heavy Metals
Rupture Curve
Sorption Modeling
Sugarcane Bagasse
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. INGENIERIA Y TECNOLOGIA
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.7.1 INGENIERIA AMBIENTAL Y GEOLOGICA
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.7 INGENIERIA DEL MEDIO AMBIENTE
metadata.dc.ucuenca.areaconocimientounescoamplio: 05 - CIENCIAS FISICAS, CIENCIAS NATURALES, MATEMATICAS Y ESTADISTICAS
metadata.dc.ucuenca.areaconocimientounescodetallado: 0521 - CIENCIAS AMBIENTALES
metadata.dc.ucuenca.areaconocimientounescoespecifico: 052 - MEDIO AMBIENTE
Issue Date: 2018
metadata.dc.ucuenca.volumen: volumen 24, número 1
metadata.dc.source: Environmental Engineering Research
metadata.dc.identifier.doi: 10.4491/eer.2018.042
metadata.dc.type: ARTÍCULO
Abstract: 
In this paper the results of the biosorption of lead(II) and cadmium(II) with sugarcane bagasse in fixed bed columns are presented. Experimental data were fitted to several models describing the rupture curve for single-component and two-component systems. The percentages of removal of lead and cadmium in single-component systems are 91% and 90%, respectively. In lead-cadmium bicomponent systems the percentage of elimination of lead was 90% and cadmium 92%. In single-component systems, Yoon-Nelson and Thomas models successfully reproduce the rupture curves. In two-component system, the Dose-Response model was the best one reproducing the experimental rupture curves in the entire measured range.
Description: 
In this paper the results of the biosorption of lead(II) and cadmium(II) with sugarcane bagasse in fixed bed columns are presented. Experimental data were fitted to several models describing the rupture curve for single-component and two-component systems. The percentages of removal of lead and cadmium in single-component systems are 91% and 90%, respectively. In lead-cadmium bicomponent systems the percentage of elimination of lead was 90% and cadmium 92%. In single-component systems, Yoon-Nelson and Thomas models successfully reproduce the rupture curves. In two-component system, the Dose-Response model was the best one reproducing the experimental rupture curves in the entire measured range.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/31806
http://eeer.org/journal/view.php?doi=10.4491/eer.2018.042
metadata.dc.ucuenca.urifuente: http://eeer.org/current/?vol=24&no=1&type=upcomming
ISSN: 1226-1025, 2005-968X (e)
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument560.93 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00