Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/30238
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCastillo Carchipulla, Edison Maximiliano-
dc.contributor.authorZaruma Uzhca, Luis Antonio-
dc.date.accessioned2018-04-25T19:10:38Z-
dc.date.available2018-04-25T19:10:38Z-
dc.date.issued2018-04-25-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/30238-
dc.descriptionLa presente investigación plantea una solución que minimice las causas para el daño en revestimientos o enlucidos de edificaciones de clima subtropical, como es el caso, de la ciudad de Zamora, en la provincia de Zamora Chinchipe, Sur Oriente del Ecuador; caracterizada por alto nivel pluviométrico y aproximadamente el 90% de humedad relativa. Esta última característica del clima, el agua de lluvia que se filtra a través del subsuelo, causa problemas patológicos en los revestimientos de no menos un 60% poco más o menos de construcciones existentes, es por esto que, se va deteriorando progresivamente la parte inferior de enlucidos interiores y en fachadas, como también disminuyendo la calidad ambiental en el interior de las viviendas. Identificado el problema se realizó la experimentación, trabajo que empieza por estudiar los morteros, que es el material del 99% en los enlucidos de edificaciones. Se analizó la mezcla con arena y cemento, misma que servirá de base o patrón para adicionarle partículas de Polietileno Tereftalato (PET), con el fin de mejorar su impermeabilidad, pero, manteniendo las características físico-mecánicas que las normas nacionales e internacionales exigen. La comparación se desarrolló con mezclas que contienen 0%, 5%, 10% y 20% de PET en la mezcla en remplazo del agregado.es_ES
dc.description.abstractThe present investigation proposes a solution that minimizes the causes for the damage in coatings or plastering of buildings of subtropical climate, as it is the case of the city of Zamora, in the province of Zamora Chinchipe, South East of Ecuador, characterized by high pluviometric level, and approximately 90% relative humidity. This last characteristic of the climate, the rainwater that filters through the subsoil, causes pathological problems in the coatings of not less than 60% of existing constructions, that is why the lower part of internal plasters is progressively deteriorating. in facades, as well as diminishing the environmental quality inside the homes. Identified the problem is the experimentation, work that begins by studying the mortars that is the material of 99% in the plastering of buildings. The mixture is analyzed with sand and cement, which will serve as a base or standard for adding polyethylene terephthalate (PET) particles, in order to improve its impermeability while maintaining the physical-mechanical characteristics that national and international standards require. The comparison was developed with mixtures containing 0%, 5%, 10% and 20% PET in the mixture in replacement of the aggregate.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTM4;1352-
dc.relation.ispartofseriesTM4;1352a (escrita)es_ES
dc.subjectArquitecturaes_ES
dc.subjectDiseño arquitectónicoes_ES
dc.subjectPlásticoses_ES
dc.subjectConstrucciónes_ES
dc.subjectMedio ambientees_ES
dc.subjectCantón Zamoraes_ES
dc.titleMortero impermeable a base de plástico reciclado PET para revestimientos de edificaciones de la ciudad de Zamoraes_ES
dc.typemasterThesises_ES
dc.ucuenca.paginacion96 páginases_ES
dc.description.degreeMagíster en Construccioneses_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0103424792es_ES
dc.ucuenca.idautor1102575287es_ES
dc.audience.educationLevelTesis de Maestría en Construccioneses_ES
Appears in Collections:Tesis Maestrías

Files in This Item:
File Description SizeFormat 
Trabajo de Titulación.pdftexto completo4.28 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00