Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/29263
Título : Chromium(VI) reduction in aqueous medium by means of catalytic membrane reactors
Autor: Pinos Velez, Veronica patricia
Palabras clave : Catalytic membrane reactors
Chromate reduction
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.10.2 Nano-Procesos [Aplicaciones a Nano-Escala]
Área de conocimiento FRASCATI específico: 2.10 NanoTecnología
Área de conocimiento UNESCO amplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
ÁArea de conocimiento UNESCO detallado: 0521 - Ciencias Ambientales
Área de conocimiento UNESCO específico: 052 - Medio Ambiente
Fecha de publicación : 2016
Volumen: Volumen 4, número 2
Fuente: Journal of Environmental Chemical Engineering
metadata.dc.identifier.doi: 10.1016/j.jece.2016.03.008
Tipo: ARTÍCULO
Abstract: 
A novel method for catalytic reduction of chromium(VI) to chromium(III) in model and real water is proposed in this work. Hydrogen was used as a reducer. Three different catalytic membrane reactors were prepared and employed in the studied reaction. The catalytic membrane reactors were prepared using commercial corundum hollow fiber membranes. The active phases, palladium, cerium oxide, iron oxide or combinations of them, were incorporated by incipient wetness impregnation of the corresponding water-soluble salts followed by calcination and reduction. The catalytic tests were performed in semi-batch mode at ambient conditions. A mass flow controller was used to supply hydrogen to one end of the membrane whilst the other end was kept closed. The reactors were submerged into a vessel containing the chromate solution. The concentration of the chromate was continuously monitored following a standard analytical method. The initial chromate concentration was varied between 0.5 and 18 mg L−1. In order to completely reduce the Cr(VI) to Cr(III), it was necessary to decrease the pH of the solution to 3. In the end of the tests the final solutions were neutralized to pH 8 and filtered. The content of chromium in the final solutions and in the precipitates was determined by inductively coupled plasma (ICP) technique. It was demonstrated that for the studied reaction the presence of palladium is essential. In all experiments, with synthetic and real water adjusted to pH 3, the catalytic membrane reactors containing palladium (0.3–0.9 w/w%) effectively reduced the chromium to levels below 0.03 mg L−1 without losing activity in repetitive runs. The results from ICP analyses demonstrated that the chromium can be completely eliminated from the water after neutralization and filtration.
URI : https://www.sciencedirect.com/science/article/pii/S2213343716300872
URI Fuente: https://www.sciencedirect.com/journal/journal-of-environmental-chemical-engineering/vol/4/issue/2
ISSN : 2213-3437
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf1.68 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00