Abstract: 
This paper reports an optical based method for quantification of cardiac motion in MRI images. The cardiac motion is quantified in a Short-Axis (SAX) slice located at the mid-cavity of the left ventricle. In this slice, the left ventricle wall is segmented for extracting the endocardium, the epicardium and the midwall. The velocity field for these contours is available after performing the optical flow estimation for the given slice. Post-processing of this motion field enables estimation of the radial displacement. The core of this cardiac motion quantification method is a sparse based algorithm for optical flow estimation. This algorithm is presented and compared with several classical optical flow estimation algorithms. The comparison is performed using several video sequences available from the Middlebury benchmark where the ground truth optical flow is known. The algorithms with better performance are also tested using a 4 D cardiac Magnetic Resonance Image (MRI) sequence. Results show that he sparse algorithm estimates an optical flow field that represents the motion of contraction during the systole interval. Moreover, results about radial displacement estimation on real MRI sequences for a normal subject and a patient with hypertrophy show that the proposed quantification method could be useful for quantification of left ventricle motion.
URI : https://www.scopus.com/inward/record.uri?eid=2-s2.0-84986203455&doi=10.1109%2fTLA.2016.7555259&partnerID=40&md5=4cc1d8c4acf1d0e80f1c3f8e88d13c9f
http://dspace.ucuenca.edu.ec/handle/123456789/29253
ISSN : 15480992
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdf168.92 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00