Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/29186
Título : The influence of gravity column continuity on the seismic performance of special steel moment frame structures
Autor: Flores Solano, Francisco Javier
Correspondencia: Charney, F.; Department of Civil and Environmental Engineering, Virginia TechUnited States; email: fcharney@vt.edu
Palabras clave : Collapse Probability
Column Splices
Continuous Stiffness
Gravity Columns
Gravity Framing
Seismic Performance
Steel Special Moment Frames
Fecha de publicación : 1-mar-2016
Fecha de fin de embargo: 1-ene-2022
Volumen: 118
Fuente: Journal of Constructional Steel Research
metadata.dc.identifier.doi: 10.1016/j.jcsr.2015.11.010
Editor: ELSEVIER LTD
Tipo: Article
Abstract: 
This paper investigates the influence of the stiffness and strength of gravity columns on the collapse performance of buildings that utilize steel special moment frames as the main seismic lateral load resisting system. The research centers on the development of a simple lumped column approach, where all the gravity columns are combined into one elastic, continuous, and pinned-base element. Once this approach was validated, 2-, 4- and 8-story buildings that were originally analyzed without the influence of gravity columns in the ATC 76-1 project were re-analyzed including gravity columns. The FEMA P-695 methodology was used to assess the collapse performance. The effect of having a different number of gravity columns and different column sections was modeled by varying the moment of inertia of the lumped gravity column. The results show that the gravity columns have a profound influence on the collapse performance of buildings, especially for taller structures. Moreover, it was found that the correlation between the results of the nonlinear static analyses and the nonlinear dynamic analysis, based on collapse evaluation, provides insight into the choice of an optimal section for the lumped column. This means, in turn, that the designer can determine the number and the size of gravity columns that are required to significantly improve the building's collapse performance.
URI : https://www.scopus.com/inward/record.uri?eid=2-s2.0-84949447794&doi=10.1016%2fj.jcsr.2015.11.010&partnerID=40&md5=8abfbc6d53677deb15d6b1002666c6a2
http://dspace.ucuenca.edu.ec/handle/123456789/29186
ISSN : 0143974X
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdf168.92 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00