Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/29049
Título : Influence of wall load-displacement shape on seismic performance of wood-frame shear wall structures
Autor: Flores Solano, Francisco Javier
Nombre de Revista: 2016 World Conference on Timber Engineering WCTE 2016
Palabras clave : Seismic Analysis
Wood Shear Wall Hysteresis Model
Wood-Frame Shear Wall Buildings
Fecha de publicación : 22-ago-2016
Fecha de fin de embargo: 1-ene-2022
Fuente: WCTE 2016 - World Conference on Timber Engineering
Editor: VIENNA UNIVERSITY OF TECHNOLOGY
Ciudad: 
Vienna
Tipo: Article
Abstract: 
The research presented in this paper investigates the influence of varying load-displacement shape on the computed FEMA P-695 seismic performance metrics including collapse margin ratio (CMR) for a subset of the woodframe shear wall building designs that were developed for the FEMA P-695 wood-frame example. Variation of loaddisplacement shape is accomplished by modification of three key parameters in the familiar 10-parameter CASHEW model: peak strength, displacement at peak strength and post yield stiffness. These parameters are varied to gain insight into trends in seismic performance for wood shear walls exhibiting different load-displacement shape compared to baseline assumptions of the FEMA P-695 wood-frame example. Investigation is conducted without P-Delta to reproduce the baseline evaluation and also with P-Delta effects included. For the range of parameters variations evaluated, it is generally observed that improving the peak strength parameter and post yield stiffness parameter has a greater effect on improving the collapse performance, as measured by CMR, than does an increase in the displacement at the peak strength parameter.
URI : https://www.scopus.com/inward/record.uri?eid=2-s2.0-85010991014&partnerID=40&md5=546e71d80a54c5f7b7f066e507d4780e
http://dspace.ucuenca.edu.ec/handle/123456789/29049
ISBN : 9783903039001
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdf168.92 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00