Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/28985
Title: Evaluating reliability of ultrashort heart rate variability parameters in metabolic syndrome subjects
Authors: Astudillo Salinas, Darwin Fabián
Palacio Baus, Kenneth Samuel
Solano Quinde, Lizandro Damian
Wong De Balzan, Sara
metadata.dc.ucuenca.nombrerevista: 21st Symposium on Signal Processing Images and Artificial Vision STSIVA 2016
Issue Date: 30-Aug-2016
metadata.dc.ucuenca.embargoend: 1-Jan-2022
metadata.dc.source: 2016 21st Symposium on Signal Processing, Images and Artificial Vision, STSIVA 2016
metadata.dc.identifier.doi: 10.1109/STSIVA.2016.7743361
Publisher: INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INC.
metadata.dc.description.city: 
Bucaramanga
metadata.dc.type: Article
Abstract: 
Heart rate variability (HRV) analysis is barely employed in healthcare environments mainly because of the lack of standard values determining the sympathovagal balance and the difficulty to register RR stationary series. Recent studies have proposed the use of shorter HRV series. For this work, we use a public metabolic syndrome subjects database retrieved during oral glucose tolerance test. In order to explore ultra-short HRV measures reliability we employ an autoregressive model using Burg method, such that short RR sequences can be evaluated while maintaining a good frequency resolution. RR, SD, rMSSD, LF, HF, LFn and LF/HF were computed for different RR sequences (10 min, 5 min, 1 min, 30 s, 10 s). To evaluate the reliability we used the intraclass correlation coefficient (ICC). Additionally, we compared the sympathovagal balance parameters (LFn, LF/HF) among the stages (basal and 30 min). Considering 10 min long registers as references, parameters obtained from 5 min long series present ICC values above 0.78 for all cases. One min long registers present ICC values above 0.70 only for temporal parameters in both RR series and rMSSD. By comparing LFn and LF/HF parameters among the basal state and 30 min, we observed a significant increase of the sympathetic tone (p < 0.05). However, these differences are important only for 10 and 5 min series. In general, we observe that temporal parameters exhibit higher reliability than those the spectral ones. Nonetheless, registers duration below one min do not present adequate results for the spectral parameters in this work.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85002669240&doi=10.1109%2fSTSIVA.2016.7743361&partnerID=40&md5=6d87785fafd0d63a1ac6aea5f0e9970d
http://dspace.ucuenca.edu.ec/handle/123456789/28985
ISBN: 9781509037971
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdf168.92 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00