Title: CFD study to determine the optimal configuration of aerators in a full-scale waste stabilization pond
Authors: Alvarado Martinez, Andrés Omar Cisneros Ramos, Juan Fernando
metadata.dc.ucuenca.correspondencia: Nopens, I.; BIOMATH, Department of Mathematical Modelling, Statistics and Bioinformatics, Ghent University, Coupure Links 653, B-9000 Gent, Belgium; email: ingmar.nopens@ugent.be
Keywords: Aeration Hydrodynamics Mixing Propeller Scenario Analysis Tracer Experiment
Issue Date: 1-Sep-2013
metadata.dc.ucuenca.embargoend: 1-Jan-2022
metadata.dc.ucuenca.volumen: 47
metadata.dc.source: Water Research
metadata.dc.identifier.doi: 10.1016/j.watres.2013.05.016
metadata.dc.type: Article
Abstract: Aerated lagoons (ALs) are important variants of the pond wastewater treatment technology that have not received much attention in the literature. The hydraulic behaviour of ALs and especially the Facultative aerated lagoons (FALs) is very complex since the aeration in these systems is designed for oxygen transfer but not necessarily to create complete mixing. In this work, the energy expenditure of the aerators was studied by means of a scenario analysis. 3D CFD models (one phase and multiphase) of a 3ha FAL in a waste stabilization pond system in Cuenca (Ecuador) were built for different configurations of aerators. The thrust produced by the aerators was modelled by an external momentum source applied as velocity vectors into the pond fluid. The predictions of a single phase model were in satisfactory agreement with experimental results. Subsequently, a scenario analysis assessing several aeration schemes with different numbers of aerators in operation were tested with respect to velocity profiles and residence time distribution (RTD) curves. This analysis showed that the aeration scheme with all 10 aerators switched on produces a similar hydraulic behaviour compared to using only 6 or 8 aerators. The current operational schemes comprise of switching off some aerators during the peak hours of the day and operating all 10 aerators during night. This current practice could be economically replaced by continuously operating 4 or 6 aerators without significantly affecting the overall mixing. Furthermore, a continuous mixing regime minimises the sediment oxygen demand enhancing the oxygen levels in the pond. © 2013 Elsevier Ltd.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84879027773&doi=10.1016%2fj.watres.2013.05.016&partnerID=40&md5=3227d91ce55dc9e34a14614b6c952c9b http://dspace.ucuenca.edu.ec/handle/123456789/22125
ISSN: 431354
Appears in Collections: Artículos
This item is protected by original copyright
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Biblioteca Campus Central
Biblioteca Campus Salud
Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00
Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00
Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00