Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/21726
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorLarriva, Wilson Giovanny-
dc.contributor.authorLazo Calle, Maritza Beatriz-
dc.contributor.authorVerdugo García, Ligia Mercedes-
dc.date.accessioned2015-04-29T12:08:38Z-
dc.date.available2015-04-29T12:08:38Z-
dc.date.issued2015-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/21726-
dc.descriptionEl presente estudio tiene como objetivo evaluar la eficiencia de los filtros durante el proceso de potabilización del aguaen la Planta de Tratamiento Uchupucun –EMAPAL-EP de la ciudad de Azogues,verificando además el cumplimiento o no de los requisitos físicos y microbiológicos contemplados en la normativa de referencia NTE INEN 1108:2011. Se realizó un estudió analítico, prospectivo, y el planteamiento de diseño es no experimental. Se analizaron 832 muestras las mismas fueron tomadas en la captación de entrada a la planta, agua pre-filtrada y agua filtrada de la planta.La frecuencia del muestreo fue dos veces por semana los días lunes y jueves, los cuales se efectuaron en un intervalo de tres horas: a las 8:00, 11:00am, y 2:00pm en un período total de 8 semanas durante los meses de Noviembre, Diciembre y Enero (17-11-2014 – 08/01/2015). Para la evaluación de la eficiencia de los filtros se analizaron los parámetros físicos (temperatura, conductividad, sólidos totales disueltos, pH, turbiedad y color) y microbiológicos(Coliformes totales y fecales) en cada una de las muestras obtenidas. En el análisis de los datos se aplicó estadística descriptiva para lo cual se utilizó el programa Stata 10.0 (StataCorporation, CollegeStation, TX). Con los resultados obtenidos se estableció que la eficiencia de los filtros es del 81% estos vienen trabajando con normalidad ya que los parámetros físicos y microbiológicos cumplen con lo establecido en la Norma INEN 1108-Agua Potable.es_ES
dc.description.abstractThe present study objective is to evaluate the efficiency of the filters during the process water purification in the treatment plant of Uchupucun-EMAPAL-EP of Azogues city, checking almost the commitment or not of the physical requirements and microbiological listed in the normative of reference NTE INEN 1108:2011 It released an analytic study, prospective and the no experimental designed approach: It was analyzed 832 samples they were totally taken in the captation at the beginning of the plant, pre-filtered water and filtered water in the plant, the frequency of sampling were twice a week on Monday and Thursday. This one interval of three hours at 8am, 11 am and 2 p.m. In a total period of 8 weeks during the months of November, December and January (17-11-2014) - (08-01-2015) For the evaluation the efficiency of the filter was analyzed with the physical parameters (temperature, connectivity, solved solids) PH muddy color and microbiological total and fecal coliforms in each one of the samples taken. In data analysis were applied descriptive statistics which is used in the program Stata 10.0 (Stata Corporation, College Station, TX). The results obtained shown that the efficiency of the filters is 81% they are working in a normal way because the physic al and microbiological parameters fulfil in established standard INEN 1108 Drinking Water.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTBQ;636-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/-
dc.subjectAgua Potablees_ES
dc.subjectPotabilizaciones_ES
dc.subjectPlanta De Tratamientoes_ES
dc.subjectCanton Azogueses_ES
dc.subjectBioquimicaes_ES
dc.titleEvaluación de la eficiencia de los filtros durante el proceso de potabilización del agua mediante análisis físico y microbiológico en la Planta de Tratamiento Uchupucun dela ciudad de Azogueses_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion146 páginases_ES
dc.description.degreeBioquímico Farmacéuticoes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102194248es_ES
dc.ucuenca.idautor0105598163es_ES
dc.ucuenca.idautor0302309422es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Tesis.pdftexto completo6.2 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00