Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/21652
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCabrera Albornoz, Fabián-
dc.contributor.authorChabla Auqui, Luis Leonardo-
dc.contributor.authorCórdova Erráez, Danny Fernando-
dc.date.accessioned2015-04-17T13:06:13Z-
dc.date.available2015-04-17T13:06:13Z-
dc.date.issued2015-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/21652-
dc.descriptionCon el incremento de la población, la demanda de energía es cada vez mayor, por lo que es necesario buscar nuevas alternativas de ahorro energético, incursionando en nuevas tecnologías que permitan minimizar el consumo de energía sin que ésta afecte en la calidad del servicio. El presente trabajo tiene como objetivo determinar el impacto energético en el alumbrado público del centro histórico de la ciudad de Cuenca, en el cual se plantea la sustitución de un nuevo sistema de alumbrado con luminarias de tecnología led y la implementación de redes de telegestión. En los capítulos 1 y 2 se muestran los principios, conceptos, fenómenos y normas que rige la luminotecnia. También se da a conocer los diferentes tipos de luminarias para alumbrado público, equipos auxiliares y lámparas. Además se analiza la tecnología led, funcionamiento, clasificación y los avances tecnológicos de los dispositivos de iluminación led en el alumbrado. En el capítulo 3 se expone los factores que determinan una instalación de alumbrado público. También se realiza el estudio del sistema actual, determinado así las condiciones de iluminación que presentan las vías del centro histórico de Cuenca. Asimismo se implementa la nueva red de iluminación con tecnología led, estableciendo parámetros comparativos entre los dos sistemas. En el capítulo 4 se describen y se realiza un análisis de sistemas de control mediante telegestión aplicable al alumbrado público del centro histórico de la ciudad de Cuenca. Finalmente el capítulo 5 presenta los criterios, conclusiones, recomendaciones y resultados obtenidos de los capítulos antes mencionados.es_ES
dc.description.abstractABSTRACT The continued increase in both population and energy demand necessitates the importance of seeking alternative energy sources that minimize the consumption of energy with no reduction in the quality of service. The present work has as its objective to determine the energy impact of public lighting in Cuenca’s historic district through the substitution of the current public lighting system with new led technology and the implementation of an integrated remote system. In chapters 1 and 2 the principles, concepts, phenomena and standards that govern lighting are explained. Also different types of public lighting, auxiliary equipment and street lights are examined. Additionally the basis of led technology, its classification and advancements in devices for public lighting that use led technology will be analyzed. Chapter 3 explores pertinent factors regarding a public lighting facility. An examination of the present lighting system is then carried out with special attention given to street lighting in Cuenca’s historic district. An opposing system of networked street lighting based upon led technology is then presented to establish comparative parameters between the two systems. In chapter 4 a description and analysis of control systems through the use of integrated remote systems applicable to public lighting in Cuenca’s historic district is given. Finally, chapter 5 presents criteria, conclusions, recommendations and obtained results from the aforementioned chapters.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTE;382-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/-
dc.subjectSistema De Iluminaciones_ES
dc.subjectAlumbrado Publicoes_ES
dc.subjectHardwarees_ES
dc.subjectEnergia Electricaes_ES
dc.subjectSistemas De Controles_ES
dc.subjectCanton Cuencaes_ES
dc.titleEficiencia energética en el alumbrado público del Centro Histórico de Cuenca: telegestión y sustitución de luminariases_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion158 páginases_ES
dc.description.degreeIngeniero Eléctricoes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102391422es_ES
dc.ucuenca.idautor0301526141es_ES
dc.ucuenca.idautor0105373617es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
tesis.pdftexto completo3.33 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00