García Ávila, Fausto FernandoRamos Fernández, LíaPauta Novillo, Alex DamianQuezada Sisalima, Diego Armando2018-06-192018-06-1920182352-3409http://dspace.ucuenca.edu.ec/handle/123456789/30566https://www.sciencedirect.com/science/article/pii/S2352340918302087This document presents the physical-chemical parameters with the objective of evaluating and analyzing the drinking water quality in the Azogues city applying the water quality index (WQI) and to research the water stability in the distribution network using corrosion indexes. Thirty samples were collected monthly for six months throughout the drinking water distribution network; turbidity, temperature, electric conductivity, pH, total dissolved solids, total hardness, calcium, magnesium, alkalinity, chlorides, nitrates, sulfates and phosphates were determined; the physical-chemical parameters were measured using standard methods. The processed data revealed that the average values of LSI, RSI and PSI were 0.5 (± 0.34), 6.76 (± 0.6), 6.50 (± 0.99) respectively. The WQI calculation indicated that 100% of the samples are considered excellent quality water. According to the Langelier, Ryznar and Pukorius indexes showed that drinking water in Azogues is corrosive. The quality of drinking water according to the WQI is in a good and excellent category.es-ESQuality IndexCorrosion IndexesWater Drinking NetworkEvaluation of water quality and stability in the drinking water distribution network in the Azogues city, EcuadorEvaluación de la calidad y estabilidad del agua en la red de distribución de agua potable en la ciudad de Azogues, EcuadorARTÍCULO10.1016/j.dib.2018.03.007