Parra González, Diego AlejandroZambrano Asanza, SergioZalamea León, Esteban FelipeBarragán Escandón, Edgar Antonio2020-05-152020-05-1520190960-1481http://dspace.ucuenca.edu.ec/handle/123456789/34310https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064932417&origin=inwardThe photovoltaic solar potential in an urban sector and the effects produced by the electricity input into a low-voltage grid are determined, the analysis is performed for one year. First, the generation profiles are estimated, assuming the incorporation limits of typical silica panels and using photovoltaic (PV) tiles on roofs as an architectural alternative. Then, the consumer class demand is estimated. Production-demand matching is performed at the load point level to avoid impacts on the grid. A scenario incorporating a new load, induction heating cookers (IHCs) for all residential users, is posed, the use of which coincides with high-radiation hours. Finally, electrical storage is assumed to maximise the PV supply. A 16% coverage with silica PV panels, or 33% with PV tiles, would supply 46% or 39% of the consumption, respectively. With massive incorporation of IHCs and storage, the supply is increased to 73% and 59 …The photovoltaic solar potential in an urban sector and the effects produced by the electricity input into a low-voltage grid are determined, the analysis is performed for one year. First, the generation profiles are estimated, assuming the incorporation limits of typical silica panels and using photovoltaic (PV) tiles on roofs as an architectural alternative. Then, the consumer class demand is estimated. Production-demand matching is performed at the load point level to avoid impacts on the grid. A scenario incorporating a new load, induction heating cookers (IHCs) for all residential users, is posed, the use of which coincides with high-radiation hours. Finally, electrical storage is assumed to maximise the PV supply. A 16% coverage with silica PV panels, or 33% with PV tiles, would supply 46% or 39% of the consumption, respectively. With massive incorporation of IHCs and storage, the supply is increased to 73% and 59 …es-ESUrban energy systemDemand side managementPhotovoltaicsSolar energySpatial distributionUrban energy systemDemand Side ManagementPhotovoltaicsSolar energySpatial distributionUrban photovoltaic potential estimation based on architectural conditions, production-demand matching, storage and the incorporation of new eco-efficient loadsARTÍCULO10.1016/j.renene.2019.03.105