Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/43758
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorOchoa Correa, Danny Vinicio-
dc.contributor.authorPachari Pacheco, José Geovanny-
dc.date.accessioned2024-01-25T12:13:18Z-
dc.date.available2024-01-25T12:13:18Z-
dc.date.issued2024-01-20-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/43758-
dc.descriptionLos sistemas eléctricos de potencia a nivel mundial, tienden a tener responsabilidad ambiental y soberanía energética, con la incorporación de energía renovables no convencionales e ingresando problemáticas de índole técnico - operativo. Al Sistema Nacional Interconectado Ecuatoriano (SNI) se analizó considerando el caso base y 4 escenarios; el caso base establece el sistema actual con generación térmica, hidráulica y eólica con 66.6MW y una demanda del sistema de 4261.20MW, se cubrió la demanda con una aportación de 91% de generación hidráulica, 8% de térmica y 1% de eólica; en el escenario 3 con una penetración de generación eólica de 647.19MW, la salida de la unidad U6 de la central Paute Molino y una demanda de 4261.20MW, se cubrió la demanda con 79% hidráulica, 7% térmica y 13% eólica, incumpliendo los límites de frecuencia permitidos por los entes de regulación en un 0.25%; para el escenario 4 considera una penetración de generación eólica de 885.10MW, salida de la unidad U6 de la central Paute Molino y una demanda de 4261.20MW cubierta con 71% hidráulica, 8% térmica y 20% eólica incumpliendo los límites de frecuencia permitidos por los entes de regulación en un 3.5%. Se realiza simulaciones en Simulink Matlab con: Criterios del caso base y los 4 escenarios considerados, agentes de generación más representativos del SNI ecuatoriano y un sistema de contribución al Control Primario de Frecuencia (CPF) para la generación eólica con inercial virtual; se obtiene mejoras importantes en el aporte a la CPF por el agente de generación eólica.en_US
dc.description.abstractElectrical power systems worldwide tend to have environmental responsibility and energy sovereignty, with the incorporation of non-conventional renewable energy and introducing technical-operational problems. The Ecuadorian National Interconnected System (SNI) was analyzed considering the base case and 4 scenarios; The base case establishes the current system with thermal, hydraulic and wind generation with 66.6MW and a system demand of 4261.20MW, the demand was covered with a contribution of 91% hydraulic generation, 8% thermal and 1% wind; In scenario 3 with a wind generation penetration of 647.19MW, the output of unit U6 of the Paute Molino plant and a demand of 4261.20MW, the demand was covered with 79% hydraulic, 7% thermal and 13% wind, failing to comply the frequency limits allowed by regulatory entities at 0.25%; For scenario 4, it considers a wind generation penetration of 885.10MW, output from unit U6 of the Paute Molino plant and a demand of 4261.20MW covered with 71% hydraulic, 8% thermal and 20% wind, failing to comply with the frequency limits allowed by regulatory entities by 3.5%. Simulations are carried out in Simulink Matlab with: Base case criteria and the 4 scenarios considered, generation agents most representative of the Ecuadorian SNI and a contribution system to the Primary Frequency Control (CPF) for wind generation with virtual inertial; Important improvements are obtained in the contribution to the CPF by the wind generation agent.en_US
dc.description.uri0000-0001-5633-1480en_US
dc.formatapplication/pdfen_US
dc.format.extent136 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofTM4;2460-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Eléctricaen_US
dc.subjectPotencia eléctricaen_US
dc.subjectSoberanía energéticaen_US
dc.subject.otherClasificación de la Investigación::Ingeniería Eléctricaen_US
dc.titleAnálisis de estabilidad de frecuencia del sistema eléctrico ecuatoriano incorporando generación eólica con escenarios de demada, generación y contingenciasen_US
dc.title.alternativeANÁLISIS DE ESTABILIDAD DE FRECUENCIA DEL SISTEMA ELÉCTRICO ECUATORIANO INCORPORANDO GENERACIÓN EÓLICA CON ESCENARIOS DE DEMANDA, GENERACIÓN Y CONTINGENCIASen_US
dcterms.descriptionMagíster en Electricidad mención Redes Eléctricas Inteligentesen_US
dcterms.spatialCuenca, Ecuadoren_US
dc.rights.accessRightsopenAccessen_US
Appears in Collections:Tesis Maestrías

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)14.33 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00