Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/30585
Title: Sephadex filtration as successful alternative to density-gradient centrifugation procedures for ram sperm selection with improved kinetics
Other Titles: Sperm selection methods in Ram
Authors: Galarza Lucero, Diego Andres
Lopez Sebastian, Antonio
Woelders, Henry
Blesbois, Elisabeth
Santiago Moreno, Julián
metadata.dc.ucuenca.correspondencia: Galarza Lucero, Diego Andres, dgalarza@ucm.es
Keywords: Sperm
Selection
Filtration
Centrifugation
Gradients
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 4. Ciencias Agrícolas
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 4.3 Medicina Veterinaria
metadata.dc.ucuenca.areaconocimientounescoamplio: 08 - Agricultura, Silvicultura, Pesca y Veterinaria
metadata.dc.ucuenca.areaconocimientounescodetallado: 0841 - Veterinaria
metadata.dc.ucuenca.areaconocimientounescoespecifico: 084 - Veterinaria
Issue Date: 2018
metadata.dc.ucuenca.volumen: número 196
metadata.dc.source: Animal Reproduction Science
metadata.dc.identifier.doi: 10.1016/j.anireprosci.2018.03.022
metadata.dc.type: ARTÍCULO
Abstract: 
Density-gradients centrifugation (DGC) and filtration columns (FC) are used to separate deformed or dead sperm, debris, and other cells that may negatively affect the fertilizing capacity of sperm in fresh, chilled and frozen/thawed semen. The present study was conducted to evaluate the suitability of DGC (BoviPure®, Percoll® and Accudenz®) and FC (Sephadex G-15®) sperm selection procedures for fresh-extended and cold-stored ram semen by assessment of post-treatment sperm quality variables. Twenty normospermic ejaculates from ten adult Merino rams were used. Sperm concentration of recovered cells was greater (P < 0.001) after BoviPure treatment than other procedures in both fresh and cold semen. With the Sephadex method, there were more desirable values than with use of DGC procedures in several sperm motility variables measured by using the CASA system. In non-refrigerated semen samples, the percentage of progressive sperm motility (%PSM) after Sephadex filtration was greater (P < 0.05) than after BoviPure treatment; the straightline velocity (VSL) value after Sephadex filtration was greater (P < 0.01) than after Accudenz treatment; the amplitude of lateral head displacement (ALH) after Sephadex and Accudenz treatment was less than non-filtered semen (P < 0.001) and after Percoll (P < 0.01) and BoviPure (P < 0.05) treatments. In cold-stored semen samples, the %PSM after Sephadex filtration was greater than non-filtered (P < 0.05) semen and after BoviPure (P < 0.05), Percoll (P < 0.05) and Accudenz (P < 0.001) treatments. It is concluded that Sephadex column filtration can be used to select ram sperm in non-refrigerated and cooled semen, because percentage progressively motile sperm and some other sperm motility characteristics are greater with use of this techniques as compared with use of DGC methods.
Description: 
Density-gradients centrifugation (DGC) and filtration columns (FC) are used to separate deformed or dead sperm, debris, and other cells that may negatively affect the fertilizing capacity of sperm in fresh, chilled and frozen/thawed semen. The present study was conducted to evaluate the suitability of DGC (BoviPure®, Percoll® and Accudenz®) and FC (Sephadex G-15®) sperm selection procedures for fresh-extended and cold-stored ram semen by assessment of post-treatment sperm quality variables. Twenty normospermic ejaculates from ten adult Merino rams were used. Sperm concentration of recovered cells was greater (P < 0.001) after BoviPure treatment than other procedures in both fresh and cold semen. With the Sephadex method, there were more desirable values than with use of DGC procedures in several sperm motility variables measured by using the CASA system. In non-refrigerated semen samples, the percentage of progressive sperm motility (%PSM) after Sephadex filtration was greater (P < 0.05) than after BoviPure treatment; the straightline velocity (VSL) value after Sephadex filtration was greater (P < 0.01) than after Accudenz treatment; the amplitude of lateral head displacement (ALH) after Sephadex and Accudenz treatment was less than non-filtered semen (P < 0.001) and after Percoll (P < 0.01) and BoviPure (P < 0.05) treatments. In cold-stored semen samples, the %PSM after Sephadex filtration was greater than non-filtered (P < 0.05) semen and after BoviPure (P < 0.05), Percoll (P < 0.05) and Accudenz (P < 0.001) treatments. It is concluded that Sephadex column filtration can be used to select ram sperm in non-refrigerated and cooled semen, because percentage progressively motile sperm and some other sperm motility characteristics are greater with use of this techniques as compared with use of DGC methods.
URI: https://www.sciencedirect.com/science/article/pii/S0378432018301362?via%3Dihub
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/animal-reproduction-science/vol/192/suppl/C
ISSN: 0378-4320
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument1.2 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00