Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/43061
Title: A Novel Fuzzy-Logic-Based Control Strategy for Power Smoothing in High-Wind Penetrated Power Systems and Its Validation in a Microgrid Lab
Authors: Ochoa Correa, Danny Vinicio
Arevalo Cordero, Wilian Paul
Keywords: Fuzzy logic control
Grid integration studies
Microgrid lab
Power smoothing
Supercapacitor
Variable-speed wind turbine
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
metadata.dc.ucuenca.areaconocimientounescodetallado: 0521 - Ciencias Ambientales
metadata.dc.ucuenca.areaconocimientounescoespecifico: 052 - Medio Ambiente
Issue Date: 2023
metadata.dc.ucuenca.volumen: Volumen 12, número 7
metadata.dc.source: Electronics
metadata.dc.identifier.doi: 10.3390/electronics12071721
metadata.dc.type: ARTÍCULO
Abstract: 
Wind power generation has undergone significant development in recent decades due to its environmental advantages and its economic competitiveness. However, its increasing level of penetration is not exempt from drawbacks, such as those derived from the fluctuating nature of the wind. To reduce its negative incidence on grid power quality and stability, different techniques have been developed, such as those based on power smoothing. In these techniques, there is a research gap on the adjustment of the time constant that adapts to the needs of the smoothing, avoiding uncertain results, computational efforts and delays in the response of the control. This paper addresses the problem, proposing a novel method for power smoothing in a wind turbine by using a fuzzy-logic-based supercapacitor storage system and time-constant fitting, with a first-order adaptive transfer function. The method considers as input variables the active power generated by the wind turbine and the state of charge of the supercapacitor, both sampled simultaneously. After a computation process, the proposal generates active power set-point values that the supercapacitor must produce to compensate for the intermittency of the wind, seen from the point of connection to the grid. The results were validated experimentally with comprehensive laboratory tests.
URI: https://www.scopus.com/record/display.uri?eid=2-s2.0-85152916358&origin=resultslist&sort=plf-f&src=s&sid=a94afbe544c0b158fe02f9b85f89dda3&sot=b&sdt=b&s=TITLE-ABS-KEY%28A+Novel+Fuzzy-Logic-Based+Control+Strategy+for+Power+Smoothing+in+High-Wind+Penetrated+Power+Systems+and+Its+Validation+in+a+Microgrid+Lab%29&sl=153&sessionSearchId=a94afbe544c0b158fe02f9b85f89dda3
metadata.dc.ucuenca.urifuente: https://www.mdpi.com/journal/electronics
ISSN: 2079-9292
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf9.11 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00