Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/42465
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Astudillo Alemán, Ana Lucía | - |
dc.contributor.author | Abad Merchán, Pamela Nicole | - |
dc.contributor.author | Ramírez Ramírez, Darleny Samanta | - |
dc.date.accessioned | 2025-12-04T22:09:29Z | - |
dc.date.available | 2024-12-05T22:09:29Z | - |
dc.date.issued | 2023-07-19 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/42465 | - |
dc.description | Este trabajo presenta la evaluación de la calidad del aire ambiente en cuatro Instituciones Educativas “Nicolas Sojos”, “Abelardo Tamariz”, “Panamá” y “Luis Cordero” del cantón Cuenca en el contexto de intervenciones de urbanismo táctico. Para este fin se determinaron las concentraciones de partículas sedimentables, niveles de presión sonora; y concentraciones de metales como Al, Mn, Zn, Fe, Co y Cr en briófitos trasplantados del género Bryum. El monitoreo de partículas sedimentables se realizó en tres etapas, superando la normativa (> 0,50 mg/cm2 *30 días) en las escuelas Luis Cordero y Abelardo Tamariz en la etapa 1, y las escuelas Panamá, Luis Cordero y Abelardo Tamariz en la etapa 2. Mientras que en la etapa 3, únicamente la escuela Abelardo Tamariz supero la normativa nacional (> 1,00 mg/cm2 *30 días). Los niveles de presión sonora registrados variaron entre 56 - 86 dB(A) excediendo las normativas nacional y local, después de implementadas las intervenciones no existieron diferencias significativas con los niveles registrados inicialmente. Respecto a las concentraciones de metales en los musgos, se registró la máxima para el Al (1 475,50 mg/kg) y la mínima para el Co (0.15 mg/kg), adicionalmente la institución educativa Abelardo Tamariz presento la máxima concentración de metales y el Zn guardo mayor relación con el tráfico rodado (r = 0,98). Las conclusiones establecen que las escuelas presentan contaminación por material sedimentable y niveles excedidos de presión sonora, y los resultados no variaron significativamente por las intervenciones de urbanismo táctico. | en_US |
dc.description.abstract | This work presents the evaluation of ambient air quality in four educational institutions: "Nicolas Sojos," "Abelardo Tamariz," "Panamá" and "Luis Cordero" in the canton of Cuenca in the context of tactical urbanism interventions. For this purpose, the concentrations of sedimentable particles, sound pressure levels, and concentrations of metals such as Al, Mn, Zn, Fe, Co, and Cr in transplanted bryophytes of the genus Bryum. The monitoring of sedimentable particles was carried out in three stages, exceeding the standard (> 0,50 mg/cm2*30 days) in the Luis Cordero and Abelardo Tamariz schools in stage 1, and the Panama, Luis Cordero, and Abelardo Tamariz schools in stage 2. In stage 3, only the Abelardo Tamariz school exceeded the national standard (> 1,00 mg/cm2*30 days). The sound pressure levels recorded varied between 56 - 86 dB(A) and were higher than national, and local regulations. After the interventions, there were no significant differences with the levels initially recorded. Regarding the concentrations of metals in the mosses, the highest concentration was for Al (1 475,50 mg/kg) and the lowest for Co (0,15 mg/kg). In addition, the Abelardo Tamariz school had the highest concentration of metals, and Zn was most related to road traffic (r = 0,98). The conclusions state that the schools present contamination by settleable material and exceeded sound pressure levels, and the results did not vary significantly by the tactical urban planning interventions. | en_US |
dc.description.uri | 0000-0002-2157-9627 | en_US |
dc.format | application/pdf | en_US |
dc.format.extent | 94 páginas | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad de Cuenca | en_US |
dc.relation.ispartof | TIA;241 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería Ambiental | en_US |
dc.subject | Calidad ambiental | en_US |
dc.subject | Biomonitorización | en_US |
dc.subject.other | CIUC::Ingenierías::Ingeniería Ambiental::Contaminación del Aire | en_US |
dc.title | Monitoreo de la calidad del aire ambiente en los accesos a cuatros escuelas del casco urbano del cantón Cuenca referente a intervenciones de urbanismo táctico | en_US |
dcterms.description | Ingeniera Ambiental | en_US |
dcterms.spatial | Cuenca | en_US |
dc.rights.accessRights | openAccess | en_US |
Appears in Collections: | Tesis de Pregrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo-de-Titulación.pdf Until 2025-12-05 | Acceso restringido (versión presentada) | 4.44 MB | Adobe PDF | View/Open Request a copy |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|