Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/42193
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBravo Calderon, Manuel Estuardo
dc.contributor.authorBravo Lozano, Ariana Lucia
dc.contributor.authorPeralta Avila, Andrea Nicole
dc.contributor.authorLima Tola, Esteban Fernando
dc.date.accessioned2023-06-16T13:14:19Z-
dc.date.available2023-06-16T13:14:19Z-
dc.date.issued2023
dc.identifier.issn2763-8405
dc.identifier.urihttps://doi.org/10.53612/recisatec.v3i6.288
dc.descriptionLa eficiencia clínica de una unidad de fotopolimerización es crucial para obtener la polimerizaciónóptima y un resultado exitoso. El objetivo de este estudio observacional fue evaluar y analizar laintensidad de la potencia lumínica de las lámparas de fotopolimerización de clínicas odontológicasprivadas de la Ciudad de Cuenca, Ecuador. La intensidad lumínica se evaluó usando el radiométroCK12024 (mide el tiempo de curado hasta 2000). Se clasificó según los siguientes parámetros: Bajorendimiento (<300mw/ cm2), rendimiento regular (300 – 800 mw/cm2) y alto rendimiento (>800mw/cm2), en un tiempo de 20 segundos y 40 segundos.Se creó una tabla en “Microsoft Excel”, con elfin de llevar un registro de todos los datos necesarios: número de lámpara, tipo de lámpara, intensidadde la potencia lumínica en 20 segundos, intensidad de la potencia lumínica en 40 segundos, fracturade fibra óptica y residuos de biomateriales sobre la fibra óptica. Se obtuvo como resultado que de las58 lámparas evaluadas, un porcentaje de 0.6% (n= 1) del total de unidades de fotopolimerizacióntienen un bajo rendimiento, un 5.2% (n=3) tiene un mediano rendimiento y un 93.1% (n= 54) de lasmismas tuvieron un alto rendimiento. Una polimerización adecuada es crucial para obtener buenaspropiedades mecánicas y físicas y excelentes resultados clínicos. De acuerdo a los resultadosobtenidos dentro del presente estudio se observa que la mayoría de lámparas de fotopolimerizaciónutilizadas en consultorios privados de la Ciudad de Cuenca, tienen un alto rendimiento clínico. (16) (PDF) ESTADO DA INTENSIDADE DA POTÊNCIA LUMINOSA DAS LÂMPADAS DE FOTOPOLIMERIZAÇÃO DE CLÍNICAS ODONTOLÓGICAS PRIVADAS DA CIDADE DE CUENCA, EQUADOR. Available from: https://www.researchgate.net/publication/371204395_ESTADO_DA_INTENSIDADE_DA_POTENCIA_LUMINOSA_DAS_LAMPADAS_DE_FOTOPOLIMERIZACAO_DE_CLINICAS_ODONTOLOGICAS_PRIVADAS_DA_CIDADE_DE_CUENCA_EQUADOR [accessed Jun 05 2023].
dc.description.abstractThe clinical efficiency of a photo polymerization unit is crucial to obtain an optimal polymerization and a successful result. The present observational study aimed to evaluate and analyze the intensity of the luminous power of the photo polymerization lamps of private dental clinics in Cuenca City, Ecuador.The luminous intensity was evaluated using the CK12024 radiometer (measured the curing time up to2000). It was classified according to the following parameters: Low performance (<300mw/cm2),regular performance (300 – 800 mw/cm2) and high performance (>800 mw/cm2), in a time of 20seconds and 40 seconds. in “Microsoft Excel”,;to register all the necessary data: number of lamp, typeof lamp, intensity of light power in 20 seconds, intensity of light power in 40 seconds, breakage of optical fiber and residues of biomaterials in the optical fiber. If you obtained as a result that of the 58lamps evaluated, a percentage of 0.6% (n=1) of the total photo polymerization units had a low performance, a 5.2% (n=3) had a medium performance and a 93.1% (n = 54) of them had a high performance. An adequate polymerization is crucial to obtain good physical and mechanical properties and excellent clinical results. According to the results obtained within the present study, it is observed that the majority of the photo polymerization lamps used in the private offices of the City of Cuenca, have a high clinical performance.
dc.language.isoes_ES
dc.sourceRECISATEC – Revista científica Saúde e tecnologia
dc.subjectIntensidad lumínica
dc.subjectLámparas de fotopolimerización
dc.subjectRendimiento clínico
dc.titleStatus of light power intensity of light curing lamps in private dentalclinics in ciudad de Cuenca, Ecuador
dc.title.alternativeESTADO DA INTENSIDADE DA POTÊNCIA LUMINOSA DAS LÂMPADAS DEFOTOPOLIMERIZAÇÃO DE CLÍNICAS ODONTOLÓGICAS PRIVADAS DA CIDADE DE CUENCA,EQUADOR
dc.typeARTÍCULO
dc.ucuenca.idautor0102137460
dc.ucuenca.idautor1105696650
dc.ucuenca.idautor0105946537
dc.ucuenca.idautor0107080707
dc.identifier.doi10.53612/recisatec.v3i6.288
dc.ucuenca.versionVersión publicada
dc.ucuenca.areaconocimientounescoamplio09 - Salud y Bienestar
dc.ucuenca.afiliacionBravo, M., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionBravo, A., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionPeralta, A., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.afiliacionLima, E., Universidad de Cuenca, Facultad de Odontología, Cuenca, Ecuador
dc.ucuenca.correspondenciaBravo Calderon, Manuel Estuardo, estuardo.bravo@ucuenca.edu.ec
dc.ucuenca.volumenVolúmen 3
dc.ucuenca.indicebibliograficoSIN INDEXAR
dc.ucuenca.numerocitaciones0
dc.ucuenca.areaconocimientofrascatiamplio3. Ciencias Médicas y de la Salud
dc.ucuenca.areaconocimientofrascatiespecifico3.2 Medicina Clínica
dc.ucuenca.areaconocimientofrascatidetallado3.2.15 Odontología
dc.ucuenca.areaconocimientounescoespecifico091 - Salud
dc.ucuenca.areaconocimientounescodetallado0911 - Estudios Dentales
dc.ucuenca.urifuentehttps://recisatec.com.br/index.php/recisatec
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf235.91 kBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00