Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/38907
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Solano León, María Katherine | - |
dc.contributor.author | Rodas Zambrano, Arelis Itzel | - |
dc.contributor.author | Peralta Bojorque, Samantha Lucía | - |
dc.date.accessioned | 2022-04-28T22:59:47Z | - |
dc.date.available | 2022-04-28T22:59:47Z | - |
dc.date.issued | 2022-04-25 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/38907 | - |
dc.description | La presión intraocular (PIO) es el resultado del equilibrio entre la producción y eliminación del humor acuoso dentro del globo ocular. La tonometría de rebote mide la PIO y permite el diagnóstico temprano y el tratamiento oportuno de enfermedades oculares, principalmente: glaucoma, la uveítis, entre otras. Los valores basales de PIO pueden variar por factores intrínsecos como edad, sexo o raza del perro y factores extrínsecos como: altitud o presión atmosférica del ambiente tomados a partir de los metros sobre el nivel del mar (msnm). El presente estudio tiene como objetivo evaluar la PIO mediante el uso de tonómetro (®️Tonovet Plus) en perros adultos con edad comprendida entre los 2 a 6 años y que no evidencien alteraciones oculares en dos pisos altitudinales (2525msnm y 319msnm). Se incluyó a 45 perros clínicamente sanos de dos ciudades del Ecuador, agrupados de acuerdo al sexo y tamaño. Se analizó de manera separada los valores de PIO del ojo derecho (PIOD) e izquierdo (PIOI). Se encontró una correlación positiva de 0.71 entre la PIOD y PIOI. La lectura media de la PIOD fue de 20.72 ± 2.34 mmHg (media ± DE) y de la PIOI fue de 20.33 ± 2.68 mmHg (media ± DE). La PIO a 2525msnm fue de 21.84±0.32 (media±E.E.), mientras que a 319 msnm fue de 19.55±0.31 (media±E.E.). La PIO de los perros evaluados en nuestro estudio es estadísticamente significativo y se relaciona con el piso altitudinal (P<0.05), sin embargo, no hubo diferencias estadísticamente significativas con relación a sexo o tamaño. Nuestro estudio demostró que existe una relación directa entre la PIO y la altitud, con una diferencia de casi 2mmHg entre los pisos altitudinales. | en_US |
dc.description.abstract | Intraocular pressure (IOP) is the result of the balance between the production and elimination of aqueous humor within the eyeball. Rebound tonometry measures IOP and allows early diagnosis and proper treatment of eye diseases, mainly: glaucoma or uveitis. Basal IOP values can vary due to intrinsic factors such as age, sex or breed of the dog and extrinsic factors such as: altitude or atmospheric pressure of the environment taken from meters above sea level (m.a.s.l). The objective of this study is to evaluate IOP using a tonometer (Tonovet Plus ®️) in adult dogs between 2 to 6 years without ocular alterations in two altitude floors (2525msnm and 319msnm). We included 45 healthy dogs from two cities of Ecuador and grouped according to sex and size. IOP values of the right eye (IOPRE) and IOP of the left eye (IOPLE) were analyzed separately. A positive correlation of 0.71 was found between IOPRE and IOPLE. The mean IOP of the right eye was 20.72 ± 2.34 mmHg (mean ± SD) and the IOP in left eye was 20.33 ± 2.68 mmHg (mean ± SD). IOP at 2525 masl was 21.84±0.32 (mean±S.E.), while at 319 masl was 19.55±0.31 (mean±S.E.). The IOP of the dogs evaluated in our study is statistically significant and is related to the altitude floor (P<0.05), however, there is no differences in relation to sex or size. Our study showed that there is a direct relationship between IOP and altitude, with a difference of almost 2mmHg between altitude floors. | en_US |
dc.format | application/pdf | en_US |
dc.format.extent | 53 páginas | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad de Cuenca | en_US |
dc.relation.ispartofseries | TV;400 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Medicina Veterinaria | en_US |
dc.subject | Perros | en_US |
dc.subject | Método estadístico | en_US |
dc.subject | Hábitat | en_US |
dc.subject.other | Oftalmología | en_US |
dc.title | Comparación de la presión intraocular (PIO) con ®Tonovet Plus en perros adultos clínicamente sanos en dos pisos altitudinales | en_US |
dc.type | bachelorThesis | en_US |
dc.description.degree | Médico Veterinario Zootecnista | en_US |
dc.description.city | Cuenca | en_US |
dc.ucuenca.id | 0104790548 | en_US |
dc.ucuenca.idautor | 2300285554 | en_US |
dc.ucuenca.idautor | 0105703029 | en_US |
dc.ucuenca.areaconocimientounescoamplio | 24 Ciencias de la Vida | en_US |
dc.ucuenca.correspondencia | arelis.itzel.rodas@gmail.com | en_US |
dc.ucuenca.correspondencia | samy_peralta@hotmail.es | en_US |
dc.ucuenca.areaconocimientounescoespecifico | 3109 Ciencias Veterinarias | en_US |
dc.ucuenca.areaconocimientounescodetallado | 3201.09 Oftalmología | en_US |
dc.rights.accessRights | openAccess | en_US |
dc.ucuenca.responsablerecepcion | Carrasco Aguilar Carmen Ximena | en_US |
Appears in Collections: | Tesis de Pregrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo de Titulacion.pdf | Versión presentada (texto completo) | 1.62 MB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|