Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/35527
Title: Optimal design and energy management for a grid connected renewable hybrid system (PV-HKT-GRID)
Authors: Arevalo Cordero, Wilian Paul
Benavides Padilla, Dario Javier
Espinoza Abad, Juan Leonardo
Jurado, Francisco
metadata.dc.ucuenca.correspondencia: Arevalo Cordero, Wilian Paul, wpac0001@red.ujaen.es
Keywords: Energy management
Energy storage
Hybrid systems
Sales
Sustainable development
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2020
metadata.dc.ucuenca.volumen: Volumen 173
metadata.dc.source: E3S Web of Conferences
metadata.dc.identifier.doi: 10.1051/e3sconf/202017302001
Publisher: EDP Sciences
metadata.dc.description.city: 
Barcelona
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
The integration of renewable energy is transcendental for sustainable development. This article analyses a hybrid grid-connected system composed of renewable energy technologies (photovoltaichydrokinetic), where several scenarios for energy management are proposed. They include a battery system as energy storage and a system without storage but with resale fee to grid, with the aim of determining the best economic and environmental balance. The results show that, by having a (PV-HKT-GRID) system with energy storage and no resale fee to the grid, the Net Present Cost (NPC) is increased by USD $ 132, 760 and the Cost of Energy (COE) decreases $ 0.013/kWh when compared to the grid. In addition, the same hybrid system without energy storage and no resale fee to grid, presents an energy cost savings of $ 0.043/kWh, and an additional cost of USD $ 43, 630. Finally, if a grid resale rate is included in the renewable hybrid system, then the difference is noticeable, the savings in the Cost of Energy is $ 0.073/kWh and presents a saving in the NPC of USD $ 39, 930. In all cases, CO2 emissions have been avoided.
URI: https://www.e3s-conferences.org/articles/e3sconf/abs/2020/33/e3sconf_icacer2020_02001/e3sconf_icacer2020_02001.html
metadata.dc.ucuenca.urifuente: https://www.e3s-conferences.org/articles/e3sconf/abs/2020/33/contents/contents.html
ISBN: 000-000-000-0
ISSN: 2267-1242
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument568.42 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00