Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/35504
Title: Comparative study of two new energy control systems based on PEMFC for a hybrid tramway in Ecuador
Authors: Arevalo Cordero, Wilian Paul
Cano Ortega, Antonio
Jurado, Francisco
metadata.dc.ucuenca.correspondencia: Jurado, Francisco, fjurado@ujaen.es
Keywords: Control
Energy management
Fuel cell
Renewable energyTramway
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2020
metadata.dc.ucuenca.embargoend: 30-Dec-2050
metadata.dc.ucuenca.volumen: Volumen 45, número 46
metadata.dc.source: International Journal of Hydrogen Energy
metadata.dc.identifier.doi: 10.1016/j.ijhydene.2020.06.212
metadata.dc.type: ARTÍCULO
Abstract: 
This article presents a comparison of two alternative systems to supply the traction power of a tramway in Cuenca–Ecuador. Each system studies the effective combination of supercapacitors, lithium ion batteries and proton exchange membrane fuel cells (SC/LIB/PEMFC) on board. The first system uses renewable sources (PV/HKT/GB/Grid) supplying the on-board systems through the existing grid and hydrogen charging stations. While the second system uses only grid power from a single point of charge, leaving the tramway without any external connection point throughout their journey. The energy and economic analyses are based on the capacity of each system to supply the load and the resources used. The results show that the new proposed control systems, by means of the analysed configurations made up of different control states, are always capable of perfectly supplying the power required by the tramway throughout their journey. However, when using energy from renewable sources, hydrogen consumption decreases by 4.27% with respect to the grid on each round trip, with a lower net present cost. Furthermore, in the first proposed system, the depth of discharge in SC and LIB is greater.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85089069034&doi=10.1016%2fj.ijhydene.2020.06.212&partnerID=40&md5=38cf017403dec79ab04703024d4ab798
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/international-journal-of-hydrogen-energy/vol/45/issue/46
ISSN: 0360-3199
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdf
  Until 2050-12-30
document232.23 kBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00