Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/35433
Title: Techno-economic evaluation of renewable energy systems combining PV-WT-HKT sources: effects of energy management under ecuadorian conditions
Authors: Arevalo, Paúl
Benavides Padilla, Dario Javier
Lata Garcia, Juan Carlos
Jurado , Francisco
metadata.dc.ucuenca.correspondencia: Jurado , Francisco, fjurado@ujaen.es
Keywords: Energy control
Hybrid systems
Optimization
Renewable energy
Sensitivity analysis
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2020
metadata.dc.ucuenca.volumen: Volumen 30, número 10
metadata.dc.source: International Transactions on Electrical Energy Systems
metadata.dc.identifier.doi: 10.1002/2050-7038.12567
metadata.dc.type: ARTÍCULO
Abstract: 
Sustainable development reached a new energy paradigm in recent decades, by promoting renewable generation technologies. The present study performs a techno-economic analysis of several hybrid energy systems that combine wind generators, photovoltaic systems, hydrokinetic turbines, lead acid batteries, and diesel generators in southern Ecuador. From real data, the sizing optimization of each renewable system was done under three proposed energy control algorithms. Then, the combinations of renewable systems are compared based on costs, energy, and environment. Additionally, this study includes several sensitivity analyzes varying the cost of the components and fuel, minimum state of charge in batteries, scaled electric load and time step to better understand the impact caused in each renewable hybrid system. The results show that a system composed of three renewable sources under load following and cycle charging energy controls, is cheaper and less polluting with respect to any combination of sources proposed. In addition to this, the systems that include photovoltaic systems and diesel generators present lower cost, 0.36 US$/kWh in the best case. To reduce the operability of the diesel generator, load following energy control is recommended. However, if diesel generator is removed, the resulting cost of 100% renewable systems increases considerably, reaching 0.88 US$/kWh. The results also show that, the variation in the capital cost of the components is directly proportional to the net present cost and cost of energy variation. Moreover, it is possible to reduce the cost of the system by discharging the batteries below their minimum state of charge. Finally, the results are more accurate when using a time step of 5 minutes.
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85089311938&doi=10.1002%2f2050-7038.12567&partnerID=40&md5=12d52e093ec4bba7ab4d185c41bcb4d8
metadata.dc.ucuenca.urifuente: https://onlinelibrary.wiley.com/toc/20507038/2020/30/1
ISSN: 2050-7038
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument231.83 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00