Title: Traditional high-rise unreinforced masonry buildings: modeling and influence of floor system stiffening on their overall seismic response
Authors: Jimenez Pacheco, Juan Carlos
González Drigo, Ramón
Pujades Beneit, Lluis Gonzaga
Barbat, Alex H
Calderon Brito, Jose Miguel
metadata.dc.ucuenca.correspondencia: Jimenez Pacheco, Juan Carlos, juan.jimenez@ucuenca.edu.ec
Keywords: Flexible floor
Pushover analysis
Spring-type macro-elements
Stiffening of floors
Traditional URM buildings
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.5.1 Ingeniería de Materiales
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.5 Ingeniería de los Materiales
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0732 - Construcción e Ingeniería Civil
metadata.dc.ucuenca.areaconocimientounescoespecifico: 073 - Arquitectura y Construcción
Issue Date: 2021
metadata.dc.ucuenca.embargoend: 7-May-2050
metadata.dc.ucuenca.volumen: Volumen 15, número 10
metadata.dc.source: International Journal of Architectural Heritage
metadata.dc.identifier.doi: 10.1080/15583058.2019.1709582
metadata.dc.type: ARTÍCULO
Abstract: 
This paper summarizes a study whose primary objectives were to develop a model for nonlinear static analysis of unreinforced masonry (URM) buildings, considering the flexibility of the floor system and analyzing the influence of stiffening the floor system on the overall seismic response of such buildings. With this aim, a six-story building typical of the Eixample-Barcelona district was used as a case study. All the macro-elements, those that constitute the walls and the floor system, were developed with one-dimensional spring elements. The influence of stiffening the floor system was analyzed by applying conventional stiffening interventions to the two-floor systems common in the Eixample-Barcelona district. The overall seismic response was evaluated in terms of modal parameters, the characteristics of the pushover curves and the deformed shape of the floors. The outcomes are discussed in relation to recent studies and explained in the context of previous studies. Finally, in the two unstiffened cases of the prototype building, the stiffening of the floor system slightly increases in fundamental periods, slightly to moderately increases in base shear capacities, and significantly decreases in displacement capacities.
Description: 
URI: https://www.tandfonline.com/doi/abs/10.1080/15583058.2019.1709582?journalCode=uarc20
metadata.dc.ucuenca.urifuente: https://www.tandfonline.com/toc/uarc20/current
ISSN: 1558-3058
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdf
  Until 2050-05-07
document5.76 MBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00