Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/34613
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAguirre Bermeo, Hernán Marcelo-
dc.contributor.authorMaldonado Yépez, Bryam Remigio-
dc.contributor.authorMartínez Muñoz, Juan Andrés-
dc.date.accessioned2020-07-07T16:33:53Z-
dc.date.available2020-07-07T16:33:53Z-
dc.date.issued2020-06-07-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/34613-
dc.descriptionAntecedentes: la broncoscopia es un procedimiento que permite observar el árbol traqueo bronquial con fines diagnósticos y terapéuticos. El broncoscopio sumado al uso de sedación puede producir complicaciones respiratorias y hemodinámicas. Estas complicaciones pueden producir una interrupción del procedimiento. La oxigenoterapia de alto flujo disminuye el trabajo respiratorio y el espacio muerto, una mejor tolerancia a la administración de flujos altos de oxígeno. Objetivo: determinar la frecuencia de complicaciones durante la fibrobroncoscopia con soporte de oxígeno terapia de alto flujo. Metodología: estudio observacional, prospectivo se investigó los beneficios de la terapia de oxígeno de alto flujo durante broncoscopia y la reducción de complicaciones, se midieron las variables: frecuencia cardiaca, frecuencia respiratoria, PAM, Sat O2, FiO2, PaO2, PaCO2, índice PaO2/FiO2, tiempo de desaturación, comodidad del paciente y operador, tasa de éxito de la broncoscopia. Con el programa bioestadístico SPSS versión 23 se realizó análisis probabilísticos. Resultados: se realizó broncoscopia a 20 pacientes en la unidad de cuidados intensivos se evidencio que el 30% de pacientes desaturo en el procedimiento y las variaciones de saturación fueron de 2.7% ± 1.94, mientras que el 25% presento alteraciones de la presión arterial y 20% taquicardia, la media de duración de la broncoscopia fue de 7:44 min ± 2:06 con una muy buena tolerancia del paciente y comodidad del operador. Conclusión: la fibrobroncoscopia con alto flujo tiene una muy buena comodidad para operador y paciente por la baja frecuencia de complicaciones y variación de saturación en comparación con estudios sin alto flujo.en_US
dc.description.abstractBackground: Bronchoscopy is a procedure that allows to observe bronchial tracheo tree for diagnostic and therapeutic purposes. The bronchoscope added to the use of sedation can produce respiratory and hemodynamic complications. These complications can cause an interruption of the procedure. High-flow oxygen therapy decreases breathing work and dead space, better tolerance to high oxygen flow administration. Objective: Determine the frequency of complications during fiber bronchoscopy with high flow oxygen therapy support. Methodology: Observational and prospective study that investigates high flow oxygen therapy benefits during bronchoscopy and complications reduction. Variables measured: heart rate, respiratory rate, MAP, Sat O2, FiO2, PaO2, PaCO2, PaO2/FiO2 index, desaturation time, patient and operator comfort, success rate of bronchoscopy. Probabilistic analyzes were performed with SPSS biostatistical program 23th version. Results: Bronchoscopy was performed on 20 patients from intensive care unit, it was observed that 30% of patients desaturated in the procedure and saturation variations were 2.7% ± 1.94; 25% had blood pressure alterations and 20% had tachycardia. Average duration of bronchoscopy was 7:44 min ± 2:06 with very good patient tolerance and operator comfort. Conclusion: High flow fibrobroncoscopy has very good comfort for operator and patient due to low frequency of complications and saturation variation compared to studies without high flow.en_US
dc.formatapplication/pdfen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesMED;2507-
dc.subjectMedicinaen_US
dc.subjectTerapia por Inhalaciónen_US
dc.subjectBroncoscopíaen_US
dc.subjectDexmedetomidinaen_US
dc.titleFrecuencia de complicaciones durante fibrobroncoscopia con soporte con ventilación de alto flujo. Hospital Vicente Corral Moscoso, 2019en_US
dc.typebachelorThesisen_US
dc.ucuenca.paginacion54 páginasen_US
dc.description.degreeMédicoen_US
dc.description.cityCuencaen_US
dc.ucuenca.id0103406419en_US
dc.ucuenca.idautor0105783039en_US
dc.ucuenca.idautor0104891775en_US
dc.type.senescytproyecto de investigaciónen_US
dc.ucuenca.correspondenciaremigiomaldonadomedicina@gmail.comen_US
dc.ucuenca.correspondenciajuanandresmartinezm@gmail.comen_US
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Proyecto de investigación.pdfversión presentada (texto completo)707.16 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00