dc.descriptionA comparative evaluation of the fatigue damage occurring in the blades of small wind turbines, with different power regulation schemes, has been conducted for the first time. Three representative test cases were built, one based on stall regulation and two using pitch regulation. The power curves were tuned to be identical in all cases, in order to allow for a direct comparison of fatigue damage. A methodology combining a dynamic simulation of a wind turbine forced by stochastic wind speed time series, with the application of the IEC 61400-2 standard, was designed and applied for two levels of turbulence intensity. The effect of the wind regime was studied by considering Weibull-distributed wind speeds with a variety of parameter sets. Not unexpectedly, in typical wind regimes, stall regulation led to a generally higher fatigue damage than pitch regulation, for similar structural blade design, but the practical implications were smaller than thought previously. Given the need for cost-effective designs for small wind turbines, stall regulation may be a viable alternative for off-grid applications. © 2019 by the authors. Licensee MDPI, Basel, Switzerland.-
dc.description.abstractA comparative evaluation of the fatigue damage occurring in the blades of small wind turbines, with different power regulation schemes, has been conducted for the first time. Three representative test cases were built, one based on stall regulation and two using pitch regulation. The power curves were tuned to be identical in all cases, in order to allow for a direct comparison of fatigue damage. A methodology combining a dynamic simulation of a wind turbine forced by stochastic wind speed time series, with the application of the IEC 61400-2 standard, was designed and applied for two levels of turbulence intensity. The effect of the wind regime was studied by considering Weibull-distributed wind speeds with a variety of parameter sets. Not unexpectedly, in typical wind regimes, stall regulation led to a generally higher fatigue damage than pitch regulation, for similar structural blade design, but the practical implications were smaller than thought previously. Given the need for cost-effective designs for small wind turbines, stall regulation may be a viable alternative for off-grid applications.-
dc.language.isoes_ES-
dc.sourceApplied Sciences (Switzerland)-
dc.subjectFatigue life-
dc.subjectSmall wind turbine-
dc.subjectAeroelastic simulation-
dc.subjectPitch regulation-
dc.subjectStall regulation-
dc.titleComparative fatigue life assessment of wind turbine blades operating with different regulation schemes-
dc.typeARTÍCULO-
dc.ucuenca.idautor0000-0003-0678-5091-
dc.ucuenca.idautor0301453486-
dc.ucuenca.idautor0000-0003-0075-8295-
dc.ucuenca.idautor0000-0002-0512-6839-
dc.ucuenca.idautorSgrp-2786-1-
dc.identifier.doi10.3390/app9214632-
dc.ucuenca.versionVersión publicada-
dc.ucuenca.areaconocimientounescoamplio07 - Ingeniería, Industria y Construcción-
dc.ucuenca.afiliacionPacheco, J., Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico-
dc.ucuenca.afiliacionProbst, O., Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico-
dc.ucuenca.afiliacionMinchala, L., Universidad de Cuenca, Departamento de Ingeniería Eléctrica, Electrónica y Telecomunicaciones(DEET), Cuenca, Ecuador-
dc.ucuenca.afiliacionCárdenas, D., Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico-
dc.ucuenca.afiliacionLoza, B., Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Monterrey, Mexico-
dc.ucuenca.volumenVolumen 9, número 21-
dc.ucuenca.indicebibliograficoSCOPUS-
dc.ucuenca.factorimpacto0.379-
dc.ucuenca.cuartilQ1-
dc.ucuenca.numerocitaciones0-
dc.ucuenca.areaconocimientofrascatiamplio2. Ingeniería y Tecnología-
dc.ucuenca.areaconocimientofrascatiespecifico2.2 Ingenierias Eléctrica, Electrónica e Información-
dc.ucuenca.areaconocimientofrascatidetallado2.2.1 Ingeniería Eléctrica y Electrónica-
dc.ucuenca.areaconocimientounescoespecifico071 - Ingeniería y Profesiones Afines-
dc.ucuenca.areaconocimientounescodetallado0714 - Electrónica y Automatización-
dc.ucuenca.urifuentehttps://www.mdpi.com/2076-3417/9/21-
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument2.99 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00