Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/34321
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVásquez, Mario-
dc.contributor.authorFlores, Cristian-
dc.contributor.authorBojorque Iñeguez, Jaime Asdrubal-
dc.date.accessioned2020-05-15T23:37:10Z-
dc.date.available2020-05-15T23:37:10Z-
dc.date.issued2019-
dc.identifier.issn07177925-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/34321-
dc.identifier.urihttp://revistadelaconstruccion.uc.cl/index.php/RDLC/article/view/2023/2097-
dc.description© 2019 Pontificia Universidad Catolica de Chile, Escuela de Construccion Civil. Highways have been and are built using Hot Mix Asphalt (HMA) as surface layer. The most common HMA design procedure is the Marshall Method, a method also used for quality control (QC) at the time of road construction. Due to several factors, sometimes it is not possible to sample the surface layer when constructed. When this occurs, QC is performed after construction by analyzing cores. Current regulations, however, fail having clear procedures regarding the collection and analysis of pavement cores after the complete placement of the asphalt mixture. For this reason, this study proposes a comparative analysis of Marshall parameters, mixture densities, and aggregates gradation obtained from specimens obtained during construction, versus cores samples extracted 30 and 60 days later. The research revealed that all the parameters measured on core samples, except flow, could be used to approve asphalt paving works after its construction.-
dc.description.abstract© 2019 Pontificia Universidad Catolica de Chile, Escuela de Construccion Civil. Highways have been and are built using Hot Mix Asphalt (HMA) as surface layer. The most common HMA design procedure is the Marshall Method, a method also used for quality control (QC) at the time of road construction. Due to several factors, sometimes it is not possible to sample the surface layer when constructed. When this occurs, QC is performed after construction by analyzing cores. Current regulations, however, fail having clear procedures regarding the collection and analysis of pavement cores after the complete placement of the asphalt mixture. For this reason, this study proposes a comparative analysis of Marshall parameters, mixture densities, and aggregates gradation obtained from specimens obtained during construction, versus cores samples extracted 30 and 60 days later. The research revealed that all the parameters measured on core samples, except flow, could be used to approve asphalt paving works after its construction.-
dc.language.isoes_ES-
dc.sourceRevista de la Construccion-
dc.subjectHot mix asphalt-
dc.subjectStability and flow-
dc.subjectQuality control-
dc.subjectPavement construction-
dc.subjectMarshall Test-
dc.titleMarshall parameters for quality control of hot mix asphalt after pavement construction-
dc.typeARTÍCULO-
dc.ucuenca.idautorSgrp-2228-2-
dc.ucuenca.idautor0102857885-
dc.ucuenca.idautorSgrp-2228-3-
dc.identifier.doi10.7764/RDLC.18.1.178-
dc.ucuenca.versionVersión publicada-
dc.ucuenca.areaconocimientounescoamplio07 - Ingeniería, Industria y Construcción-
dc.ucuenca.afiliacionVásquez, M., Investigador Independiente, Cuenca, Ecuador-
dc.ucuenca.afiliacionBojorque, J., Universidad de Cuenca, Departamento de Ingeniería Civil, Cuenca, Ecuador-
dc.ucuenca.afiliacionFlores, C., Investigador Independiente, Cuenca, Ecuador-
dc.ucuenca.correspondenciaBojorque Iñeguez, Jaime Asdrubal, jaime.bojorque@ucuenca.edu.ec-
dc.ucuenca.volumenVolumen 18, Número1-
dc.ucuenca.indicebibliograficoSCOPUS-
dc.ucuenca.factorimpacto0.27-
dc.ucuenca.cuartilQ3-
dc.ucuenca.numerocitaciones61-
dc.ucuenca.areaconocimientofrascatiamplio2. Ingeniería y Tecnología-
dc.ucuenca.areaconocimientofrascatiespecifico2.1 Ingeniería Civil-
dc.ucuenca.areaconocimientofrascatidetallado2.1.5 Ingeniería de Transporte-
dc.ucuenca.areaconocimientounescoespecifico073 - Arquitectura y Construcción-
dc.ucuenca.areaconocimientounescodetallado0732 - Construcción e Ingeniería Civil-
dc.ucuenca.urifuentehttp://revistadelaconstruccion.uc.cl/index.php/RDLC/index-
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument564.67 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00