Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/32951
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSajo Bohus, Laszlo-
dc.contributor.authorSerrano Pérez, Elsa Cristina-
dc.date.accessioned2019-07-04T22:24:02Z-
dc.date.available2019-07-04T22:24:02Z-
dc.date.issued2019-07-04-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/32951-
dc.descriptionFuentes de neutrones de medidores nucleares de densidad y humedad (MNDH), son ampliamente utilizados en la industria de la construcción. El control de exposición a estas radiaciones no se realiza en el Ecuador. El objetivo del estudio fue determinar la dosis equivalente y efectiva de mencionada fuente, mediante detectores pasivos PADC (CR-39TM) y compararlas con límites permitidos. El estudio fue de tipo experimental. La emisión de radiación de neutrones por un MNDH (Troxler modelo 3430) se evaluó empleando detectores CR-39™ para identificar densidad de trazas y calcular las dosis requeridas. La eficiencia del CR-39™ fue evaluada al comparar dos tipos de conversores de 10B (pastilla vs. cinta engomada) y seleccionar el más eficiente. Se ensamblaron 11 detectores, usando cinta engomada y lámina de cadmio, para ubicarlos en diferentes posiciones simulando la exposición de un operador. Se determinó que los promedios de densidades de trazas identificadas con pastilla de boro vs. cinta engomada no fueron diferentes (valor p >0.05). Se empleó el conversor más eficiente según menor costo, la cinta engomada. La dosis equivalente más alta calculada fue para la mano en contacto con el equipo (17.04±2.04μSv/h) y la menor para el rostro con el operador de pie (4.12±0.49μSv/h). Las dosis equivalente “total” y dosis efectiva “jornadas de 8 horas” estuvieron por debajo de los límites permisibles (199.09±23.89 mSv/año < 500 mSv/año y 18.50±2.22 mSv/año < 20 mSv, respectivamente). En conclusión, las dosis equivalente y efectiva fueron menores que los límites permisibles, sin embargo resulta importante medir las radiaciones de neutrones que pudieran afectar la salud de los trabajadores expuestos a nivel laboral.es_ES
dc.description.abstractNeutron sources of nuclear density and moisture gauges (NDMG), are widely used in construction industry. The exposure control to this type of ionizing radiation is not carried out in Ecuador. The aim of the study was to determine the equivalent and effective dose of the neutron source of an NDMG by passive PADC detectors (CR-39TM) and compare them with the permitted limits. The study was experimental. The emission of neutron was evaluated by an NDMG brand (Troxler model 3430) using CR-39TM to identify trace density and calculate the required doses. The efficiency of the CR-39TM was evaluated by comparing two types of Boron converters (pill vs. adhesive tape) and selecting the most efficient one. Eleven detectors were assembled, using adhesive tape and cadmium foil, and located in different positions simulating the exposure of an operator. The study determined that the average densities of traces identified with boron pill vs. adhesive tape were not statistically different (p value> 0.05). The most efficient converter was used for lower cost reason, the adhesive tape. The highest equivalent dose was for the hand in contact with the equipment (17.04 ± 2.04μSv/h) and the lowest for the face with the operator standing (4.12 ± 0.49μSb/h). The "total" equivalent doses and "8 work hour" effective dose were below the permissible limits (199.09 ± 23.89 mSv / year <500 mSv and 18.50 ± 2.22 mSv / year <20 mSv, respectively). In conclusion, the doses emitted by the neutron sources was lower than the permissible limits. However, it is important to measure ionizing neutron radiation that could affect the health of workers exposed at work.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTM4;1575-
dc.subjectNeutroneses_ES
dc.subjectRiesgo Radiologicoes_ES
dc.subjectDosis Equivalentees_ES
dc.subjectCr-39es_ES
dc.subjectMedidor Nuclear De Densidad Y Humedades_ES
dc.titleDosis equivalente de los operadores de medidores nucleares de densidad y humedad debida a la fuente de neutrones, usando detectores pasivos de policarbonato CR-39 TMes_ES
dc.typemasterThesises_ES
dc.ucuenca.paginacion68 páginases_ES
dc.description.degreeMagíster en Seguridad e Higiene Industriales_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id02940749es_ES
dc.ucuenca.idautor0102814373es_ES
dc.audience.educationLevelTesis de Maestría en Seguridad e Higiene Industriales_ES
Appears in Collections:Tesis Maestrías

Files in This Item:
File Description SizeFormat 
Trabajo de Titulación.pdftexto completo2.41 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00