Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/31973
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorPalacios Astudillo, Iván Andrés-
dc.contributor.authorRodas Jaramillo, Anabel Priscila-
dc.contributor.authorVillalta Mendoza, Fernando Mauricio-
dc.date.accessioned2019-02-08T22:37:41Z-
dc.date.available2019-02-08T22:37:41Z-
dc.date.issued2019-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/31973-
dc.descriptionLa intensidad lumínica es importante para la activación de biomateriales fotosensibles y su valor mínimo es de 400mW/cm2. Las lámparas más comunes son Halógenas y LED. La presencia de fracturas o residuos de biomateriales sobre la fibra óptica de las mismas, pueden afectar su intensidad lumínica. MATERIALES Y MÉTODOS: La muestra fue de 366 unidades, se determinó el tipo de lámpara, marca comercial, modelo, presencia o ausencia de fracturas y residuos de biomateriales sobre la fibra óptica. El radiómetro dental Bluephase Meter II, determinó el diámetro de la fibra y la intensidad lumínica. Los datos obtenidos fueron analizados con el programa IBM SPSS Stadistics versión 23. RESULTADOS: El 67,2% tenían intensidad adecuada y 32,8% inadecuada. Además, 19,1% eran lámparas halógenas y 80,9% LED. En cambio, 64,7% de unidades presentaban fibra óptica con diámetro de 8 mm; 15,6% de 9 mm; 12% de 10 mm; 2,2% de 11 mm y 5,5% de 12mm. Aparte, 78,7% no tenían fracturas de la fibra óptica, pero 21,3% si las presentaban. Finalmente, 55,5% presentaban residuos de biomateriales dentales sobre la fibra óptica y 44,5% estaban libres de ellos. CONCLUSIONES: El 32,8% de dispositivos tenían intensidades menores de 400 mW/cm2, con un mayor porcentaje de lámparas halógenas respecto a las LED. Las fibras ópticas con diámetros de 8 y 9 mm, representaron los mayores porcentajes. La intensidad lumínica puede afectarse por la presencia de fracturas o residuos de biomateriales dentales sobre la fibra óptica.es_ES
dc.description.abstractThe luminous intensity is important for the activation of photosensitive biomaterials and its minimum value is 400mW/cm2. The most common lamps are Halogen and LED. The presence of fractures or residues of biomaterials on their optical fiber can affect their light intensity. MATERIALS AND METHODS: The sample was 366 units, the type of lamp, trademark, model, presence or absence of fractures and residues of biomaterials on optical fiber was determined. The dental radiometer Bluephase Meter II, determined the diameter of the fiber and the light intensity. The data obtained was analyzed with the IBM SPSS Stadistics version 23 program. RESULTS: 67.2% had adequate intensity and 32.8% inadequate. In addition, 19.1% were halogen lamps and 80.9% LED. In contrast, 64.7% of units had optical fiber with a diameter of 8 mm; 15.6% of 9 mm; 12% of 10 mm; 2.2% of 11mm and 5.5% of 12mm. In addition, 78.7% did not have fiber optic fractures, but 21.3% did. Finally, 55.5% had residues of dental biomaterials on the optical fiber and 44.5% were free of them. CONCLUSIONS: 32.8% of devices had intensities lower than 400 mW / cm2, with a higher percentage of halogen lamps than LEDs. The optical fibers with diameters of 8 and 9 mm, represented the highest percentages. The light intensity can be affected by the presence of fractures or residues of dental biomaterials on the optical fiberes_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesODON;638-
dc.subjectIntensidad Luminicaes_ES
dc.subjectLamparas De Fotopolimerizaciones_ES
dc.subjectRadiometro Dentales_ES
dc.titleEvaluación de la intensidad lumínica generada por lámparas de fotopolimerización utilizadas en consultorios privados de la ciudad de Cuenca. 2018es_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion51 páginases_ES
dc.description.degreeOdontólogoes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0104052386es_ES
dc.ucuenca.idautor0106637929es_ES
dc.ucuenca.idautor0105836167es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo de titulación.pdfTexto completo1.91 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00