Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/31171
Título : Sperm selection by density-gradient centrifugation of merino ram semen cold-stored up to 48 h improves viability and membrane integrity
Otros títulos : Selección espermática por centrifugación de gradientes de densidad de semen de carnero Merino almacenado en frio hasta por 48 h mejora la viabilidad e integridad de la membrana
Autor: Galarza Lucero, Diego Andres
Rizos, Dimitrios
Lopez Sebastian, Antonio
Santiago Moreno, Julián
Ladron de guevara, Magdalena
Beltran Breña, Paula
Correspondencia: Galarza Lucero, Diego Andres, dgalarza@ucm.es
Palabras clave : Sperm
Cold-Storage
Selection
Área de conocimiento FRASCATI amplio: 4. Ciencias Agrícolas
Área de conocimiento FRASCATI específico: 4.3 Medicina Veterinaria
Área de conocimiento UNESCO amplio: 08 - Agricultura, Silvicultura, Pesca y Veterinaria
ÁArea de conocimiento UNESCO detallado: 0841 - Veterinaria
Área de conocimiento UNESCO específico: 084 - Veterinaria
Fecha de publicación : 2018
Volumen: volumen 15, número 3
Fuente: Animal Reproduction (Physiology of Reproduction in Male and Semen Technology)
metadata.dc.identifier.doi: 
Ciudad: 
Nantes
Tipo: ARTÍCULO DE CONFERENCIA
Abstract: 
Liquid ram semen stored at 5ºC would be more competent than frozen/thawed for sheep crossbreeding programs. The aim was to evaluate the kinetics and membrane integrity of Merino ram semen cold-stored up to 48h at 5ºC before and after density-gradient centrifugation (DGC) selection. Pools of 3 normospermic Merino ram (2-7 years) ejaculates were collected by artificial vagina in fifteen sessions (45 ejaculates), diluted to 200x106 spermatozoa/ml with skim milk-based extender contained 6% egg yolk and cold-stored up to 48h at 5ºC. Motile spermatozoa were separated by BoviPure DGC (Galarza et al., 2018, Anim Reprod Sci 192: 261-270) using 250ul of fresh (n = 30) and cold-stored semen (24h: n = 10 and 48h: n = 10). The final pellet of 300ul was used to assess semen quality. The kinetic parameters were evaluated by computer-assisted sperm analysis (CASA) while plasma, acrosomal and mitochondrial membrane status was analyzed by PI/FITC PNA/Mitotracker fluorescence. The effects of storage time (fresh, 24 & 48h) and sperm selection process were analysed by univariant ANOVA and Bonferroni´s test (P < 0.05). In terms of sperm storage time, CASA analysis of non-selected semen samples showed a significant decrease after storage for 24 and 48h compared to fresh samples with regard to progressive motility [SPM (%): 52.30 ± 4.1 and 36.9 ± 5.5 vs 71.3 ± 1.6], straight line velocity [VSL (um/sec): VSL 132.2 ± 6.1 and 109.7 ± 6.3 vs 176.7 ± 4.3], linearity [LIN (%): 69.2 ± 3.5 and 59.0 ± 5.0 vs 82.0 ± 1.2], and straightness [STR (%): 75.7 ± 3.3 and 66.0 ± 4.3 vs 86.9 ± 0.9], respectively. However, analysis of DGC-selected semen showed a decrease only at storage for 48h when compared to 24h or fresh samples with regards to SPM (35.6 ± 3.9 vs 56.1 ± 6.91 and 59.3 ± 2.6), VSL (83.5 ± 4.4 vs 105.3 ± 6.5 and 110 ± 2.0) and LIN (63.9 ± 3.4 vs 75.0 ± 3.7 and 80.7 ± 2.4), respectively. A comparison between DGCselected and non-selected samples showed a significant lower total motility [TM (%): 94.4 ± 0.8 vs 85.4 ± 1.90], VSL (176.7 ± 4.2 vs 110.0 ± 2.0) and wobble [WOB (%): 94.2 ± 0.6 vs 88.5 ± 1.5] only for fresh semen. Fluorescence analysis evidenced a decrease only in 24h cold-stored non-selected compared with fresh semen with regard to plasma membrane integrity [PMI (%): 64.8 ± 2.9 vs 80.1 ± 1.7], high mitochondrial function [HMF (%): 88.2 ± 1.6 vs 93.9 ± 1.0] and total intact plasma/intact acrosome/high mitochondrial function [IPIAHM (%): 61.8 ± 3.1vs 78.7 ± 2.0]. In contrast, no differences were observed between fresh and cold-stored DGC-selected semen. A comparison between selected and non-selected semen showed a significant increase of PMI (64.8 ± 3.14 to 89.4 ± 2.32), HMF (88.2 ± 1.26 to 96.0 ± 1.26) and IPIAHM (61.8 ± 3.14 to 87.6 ± 2.04) only for 24h. These results suggest that kinetic activity of cold-stored and DGC-selected ram spermatozoa is maintained and the selection process results in improved viability and membrane integrity. Therefore, liquid storage combined with DGC selection might become a good alternative to fresh or frozen non-selected semen to be used for artificial insemination in sheep crossbreeding programs.
Resumen : 
Liquid ram semen stored at 5ºC would be more competent than frozen/thawed for sheep crossbreeding programs. The aim was to evaluate the kinetics and membrane integrity of Merino ram semen cold-stored up to 48h at 5ºC before and after density-gradient centrifugation (DGC) selection. Pools of 3 normospermic Merino ram (2-7 years) ejaculates were collected by artificial vagina in fifteen sessions (45 ejaculates), diluted to 200x106 spermatozoa/ml with skim milk-based extender contained 6% egg yolk and cold-stored up to 48h at 5ºC. Motile spermatozoa were separated by BoviPure DGC (Galarza et al., 2018, Anim Reprod Sci 192: 261-270) using 250ul of fresh (n = 30) and cold-stored semen (24h: n = 10 and 48h: n = 10). The final pellet of 300ul was used to assess semen quality. The kinetic parameters were evaluated by computer-assisted sperm analysis (CASA) while plasma, acrosomal and mitochondrial membrane status was analyzed by PI/FITC PNA/Mitotracker fluorescence. The effects of storage time (fresh, 24 & 48h) and sperm selection process were analysed by univariant ANOVA and Bonferroni´s test (P < 0.05). In terms of sperm storage time, CASA analysis of non-selected semen samples showed a significant decrease after storage for 24 and 48h compared to fresh samples with regard to progressive motility [SPM (%): 52.30 ± 4.1 and 36.9 ± 5.5 vs 71.3 ± 1.6], straight line velocity [VSL (um/sec): VSL 132.2 ± 6.1 and 109.7 ± 6.3 vs 176.7 ± 4.3], linearity [LIN (%): 69.2 ± 3.5 and 59.0 ± 5.0 vs 82.0 ± 1.2], and straightness [STR (%): 75.7 ± 3.3 and 66.0 ± 4.3 vs 86.9 ± 0.9], respectively. However, analysis of DGC-selected semen showed a decrease only at storage for 48h when compared to 24h or fresh samples with regards to SPM (35.6 ± 3.9 vs 56.1 ± 6.91 and 59.3 ± 2.6), VSL (83.5 ± 4.4 vs 105.3 ± 6.5 and 110 ± 2.0) and LIN (63.9 ± 3.4 vs 75.0 ± 3.7 and 80.7 ± 2.4), respectively. A comparison between DGCselected and non-selected samples showed a significant lower total motility [TM (%): 94.4 ± 0.8 vs 85.4 ± 1.90], VSL (176.7 ± 4.2 vs 110.0 ± 2.0) and wobble [WOB (%): 94.2 ± 0.6 vs 88.5 ± 1.5] only for fresh semen. Fluorescence analysis evidenced a decrease only in 24h cold-stored non-selected compared with fresh semen with regard to plasma membrane integrity [PMI (%): 64.8 ± 2.9 vs 80.1 ± 1.7], high mitochondrial function [HMF (%): 88.2 ± 1.6 vs 93.9 ± 1.0] and total intact plasma/intact acrosome/high mitochondrial function [IPIAHM (%): 61.8 ± 3.1vs 78.7 ± 2.0]. In contrast, no differences were observed between fresh and cold-stored DGC-selected semen. A comparison between selected and non-selected semen showed a significant increase of PMI (64.8 ± 3.14 to 89.4 ± 2.32), HMF (88.2 ± 1.26 to 96.0 ± 1.26) and IPIAHM (61.8 ± 3.14 to 87.6 ± 2.04) only for 24h. These results suggest that kinetic activity of cold-stored and DGC-selected ram spermatozoa is maintained and the selection process results in improved viability and membrane integrity. Therefore, liquid storage combined with DGC selection might become a good alternative to fresh or frozen non-selected semen to be used for artificial insemination in sheep crossbreeding programs.
URI : http://www.cbra.org.br/portal/downloads/publicacoes/animalreproduction/issues/download/v15/v15n3/p554-562%20-%20(A173-A181%20Physiology%20...)%20=AETE.pdf
URI Fuente: http://www.cbra.org.br/portal/publicacoes/ar/2018/ar2018v15n3.html
ISSN : 1984-3143
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument169.1 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00