dc.description | Objetivo: Comparar el grado de microfiltración de RelyX U200 (3M) y Multilink N (Ivoclar Vivadent) en dientes bovinos mediante estereomicroscopio. Materiales y Métodos: Se elaboraron estructuras de dióxido de zirconio (Vipi Block Zirconn) mediante Cerec Sirona Cad-Cam (Diseño Asistido por computadora – Fabricación Asistida por Computadora), que posteriormente fueron cementadas, divididas en dos grupos de forma aleatoria (20 con el cemento Multilink y 20 con el cemento U200), las mismas fueron seccionadas para ser observadas mediante estereomicroscopio, luego se midió la microfiltración que presentaron las estructuras en mm2 mediante el programa AutoCad. Resultados: Al realizar la comparación de la microfiltración entre el cemento Multilink (0,192 mm2) y U200 (0,225 mm2) se concluyó que no existe una diferencia estadísticamente significativa. Conclusión: De acuerdo a los resultados del presente estudio los cementos con monómeros fosfato en su composición son los que menor microfiltración presentaron en la cementación de estructuras a base de dióxido de zirconio. | es_ES |
dc.description.abstract | Aim: To compare the filtration degree of RelyX U200 (3M) and Multilink N (Ivoclar Vivadent) in bovine teeth by stereomicroscope technique. Materials and Methods: Twenty Zirconium dioxide structures (Vipi Block Zirconn) were elaborated by Cerec Sirona Cad-Cam (Computer Aided Design - Computer Aided Manufacturing) which were subsequently cemented, they were randomly divided into two groups (20 with Multilink cement and 20 with Relyx U200 cement), the same that were sectioned to be observed by stereomicroscope, then measured the microfiltration that presented the structures in mm2 using the AutoCad computational program. Results: Comparison between the Multilink cement (0,192 mm2) and U200 (0,225 mm2), shows that there is no statistically significant difference. Conclusion: Cements with phosphate monomers in their composition are suitable for cementation of structures based on zirconium dioxide | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.relation.ispartofseries | ODONRO;16 | - |
dc.subject | Microfiltracion | es_ES |
dc.subject | Dioxido De Zirconio | es_ES |
dc.subject | U200 | es_ES |
dc.subject | Multilink | es_ES |
dc.title | Microfiltración de estructuras unitarias de dióxido de zirconio con dos tipos de cemento resinoso. | es_ES |
dc.type | masterThesis | es_ES |
dc.ucuenca.paginacion | 83 páginas | es_ES |
dc.description.degree | Especialista en rehabilitación oral | es_ES |
dc.description.city | Cuenca | es_ES |
dc.ucuenca.id | 1103709356 | es_ES |
dc.ucuenca.idautor | 0104841184 | es_ES |
Appears in Collections: | Tesis Especializaciones |
This item is protected by original copyright |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|