Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/28995
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Fajardo, J | - |
dc.contributor.author | Astudillo Salinas, Darwin Fabián | - |
dc.contributor.author | Palacio Baus, Kenneth Samuel | - |
dc.contributor.author | Solano Quinde, Lizandro Damian | - |
dc.contributor.author | Wong De Balzan, Sara | - |
dc.date.accessioned | 2018-01-11T16:47:05Z | - |
dc.date.available | 2018-01-11T16:47:05Z | - |
dc.date.issued | 2016-10-19 | - |
dc.identifier.isbn | 9781509025312 | - |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015254624&doi=10.1109%2fANDESCON.2016.7836245&partnerID=40&md5=da90c132770862948c74e5b6fe481ffc | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/28995 | - |
dc.description.abstract | In this paper, we evaluated two well-known QRS algorithms: Pan & Tompkins (PT) and based wavelet transform (WT) on an ECG stress test database. In the absence of an annotated ECG stress test database, the first stage of this work consisted of the database annotation, using RR-time series obtained from an eight leads stress database (DICARDIA). First, the system proposes to users a lead (reference channel) according to its statistical measures. Then the user realizes a visual inspection aimed at validating or denying the channel proposed by the system. As the series contains few artifacts, the annotation is performed using interval of annotations. Preliminary results realized over 31928 beats provide a sensibility of 99.81% and 98.28% respectively for PT and WT. The procedure developed in this work can be seen as a valuable starting point in semiautomatic annotation of large electrocardiographic databases, as well to evaluate and to improve stress ECG delineations. | - |
dc.language.iso | en_US | - |
dc.publisher | INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INC. | - |
dc.source | Proceedings of the 2016 IEEE ANDESCON, ANDESCON 2016 | - |
dc.title | Evaluation of two QRS detection algorithm on ECG stress test database | - |
dc.type | Article | - |
dc.description.city | Arequipa | - |
dc.ucuenca.idautor | 0103907036 | - |
dc.ucuenca.idautor | 0103566360 | - |
dc.ucuenca.idautor | 0102428893 | - |
dc.ucuenca.idautor | 081929618 | - |
dc.identifier.doi | 10.1109/ANDESCON.2016.7836245 | - |
dc.ucuenca.embargoend | 2022-01-01 0:00 | - |
dc.ucuenca.afiliacion | fajardo, j., electronic engineering and telecommunications school, faculty of engineering, university of cuenca, ecuador | - |
dc.ucuenca.afiliacion | astudillo, d., electronic engineering and telecommunications school, faculty of engineering, university of cuenca, ecuador, department of electrical, electronic engineering and telecommunications, university of cuenca, ecuador | - |
dc.ucuenca.afiliacion | palacio-baus, k., electronic engineering and telecommunications school, faculty of engineering, university of cuenca, ecuador, department of electrical, electronic engineering and telecommunications, university of cuenca, ecuador | - |
dc.ucuenca.afiliacion | solano-quinde, l., electronic engineering and telecommunications school, faculty of engineering, university of cuenca, ecuador, department of electrical, electronic engineering and telecommunications, university of cuenca, ecuador | - |
dc.ucuenca.afiliacion | wong, s., department of electrical, electronic engineering and telecommunications, university of cuenca, ecuador, prometeo project researcher, senescyt, ecuador | - |
dc.ucuenca.indicebibliografico | SCOPUS | - |
dc.ucuenca.nombrerevista | 2016 IEEE ANDESCON ANDESCON 2016 | - |
Appears in Collections: | Artículos |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
documento.pdf | 168.92 kB | Adobe PDF | View/Open |
This item is protected by original copyright |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|