dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/28843-
dc.descriptionLas redes de distribución de agua potable cuentan con tuberías de cobre comúnmente utilizadas en las ramificaciones de la red principal hasta los domicilios de los usuarios (conexiones domiciliarias). Las cuales al estar expuestas a las características agresivas del agua que transportan tienden a ocasionar un desgaste debido a los procesos corrosivos que se originan en el interior de las tuberías. El objetivo de este trabajo fue establecer una relación entre la variación de la tasa de corrosión que ocurre en el interior de las tuberías de cobre y la concentración de cloro residual presente en el agua potable de la red de distribución. Se instalaron cupones de corrosión de cobre en tres lugares con concentraciones diferentes de cloro residual. De esta manera se evaluó la pérdida de peso de cada cupón para establecer tasas de corrosión en distintos periodos de exposición. Mediante regresión lineal se observó que a medida que la concentración de cloro en el agua es mayor, la variación de la tasa de corrosión y la liberación de cobre disuelto de los cupones aumenta. Así se obtuvieron ecuaciones de la tasa de corrosión para distintos periodos de exposición, esto permitió evaluar el proceso corrosivo que se da en una red de distribución conociendo la concentración de cloro residual presente en el agua potable de distribución. Se determinó las zonas más propensas a fallas en los sistemas de tuberías de las conexiones domiciliarias, así como la vida útil de las mismas.es_ES
dc.description.abstractDrinking water distribution networks have copper pipes commonly used in the branches of the main network to the users homes (home connections). When it are exposed to the aggressive characteristics of the water they transport; the water tend to cause wear due to the corrosive processes that originate inside the pipes. The objective of this work was to establish a relationship between the variation of the corrosion rate that occurs inside the copper pipes with the concentration of residual chlorine present in the drinking water of the distribution network. Copper corrosion coupons were installed in three locations with different concentrations of residual chlorine. In this way, the weight loss of each coupon was evaluated to establish corrosion rates in different periods of exposure. By linear regression it was observed that as the concentration of chlorine in the water increases, the variation of the corrosion rate and the release of dissolved copper from the coupons increases. Thus, equations of the corrosion rate for different periods of exposure were obtained, this allowed to evaluate the corrosive process that occurs in a distribution network knowing the concentration of residual chlorine present in the drinking water distribution. Also, was determined the areas most prone to failures in the piping systems of the residential connections, as well as their useful life.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTIA;97-
dc.subjectIngenieria Ambientales_ES
dc.subjectTuberias de cobrees_ES
dc.subjectCloroes_ES
dc.subjectAgua potablees_ES
dc.subjectConexiones domiciliariases_ES
dc.subjectCorrosiónes_ES
dc.titleEfecto del cloro en las tuberías domiciliarias de cobre expuestas al agua potablees_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion83 páginases_ES
dc.description.degreeIngeniero Ambientales_ES
dc.description.cityCuencaes_ES
dc.ucuenca.idautor0105730527es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
TESIS.pdftexto completo7.84 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00