Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/28130
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Vega Yépez, Andrés Gustavo | - |
dc.contributor.author | Ortiz Garay, Elida Magaly | - |
dc.date.accessioned | 2017-09-15T14:41:54Z | - |
dc.date.available | 2017-09-15T14:41:54Z | - |
dc.date.issued | 2017 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/28130 | - |
dc.description | Objetivo: Comparar la eficacia de la aguja de extremo abierto (Flat), con la aguja de extremo abierto con muesca (Notched) y la aguja de extremo cerrado con ventilación lateral (Side-Port) en la remoción de debris del tercio apical en dientes bovinos. Materiales y Métodos: Se realizó un estudio in vitro transversal, usando 108 dientes bovinos los cuales se estandarizaron a una longitud de 16mm y fueron preparados apicalmente hasta una lima K #60, se dividieron longitudinalmente y se creó un surco en el tercio apical del segmento vestibular, el cual fue llenado con una mezcla de debris e irrigante, los dientes se re-ensamblaron y fueron distribuidos al azar en tres grupos para ser irrigados con 8ml de hipoclorito de sodio al 5,25% usando tres diferentes tipos de agujas, finalmente se secaron con puntas de papel. Se desensamblaron los dientes para ser observados y tomar fotografías de los surcos bajo el estereomicroscopio a 30x. La evaluación de la eficacia de la remoción de debris fue realizada por dos observadores cegados y previamente calibrados mirando las imágenes obtenidas usando la puntuación descrita por van der Sluis. La tabulación y el análisis de datos se realizó en “SPSS vs.20” y se ejecutó la prueba estadística Chi Cuadrado | es_ES |
dc.description.abstract | Objective: Compare the efficacy of the open-end needle (Flat) with the notched open-end needle (Notched) and the closed-end needle with lateral ventilation (Side-port) in the removal of debris of the apical third on bovine teeth. Materials and Methods: A transverse in vitro study was performed using 108 bovine teeth which were standardized to a length of 16mm and were apically prepared to a K # 60 file, were longitudinally divided and a groove was created in the apical third of the vestibular segment, which was filled with a mixture of debris and irrigant, the teeth were reassembled and distributed in three groups to be irrigated with 8ml of 5.25% sodium hypochlorite using three types of needles, finally dried with paper points . The teeth were disassembled for observation and take photographs of the grooves under the stereomicroscope at 30x. The evaluation of the effectiveness of debris removal was performed by two blinded and previously calibrated observers looking at the images obtained using the score described by van der Sluis. The tabulation and data analysis was performed in "SPSS vs.20" and the Chi Square test was performed | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.relation.ispartofseries | ODONEN;12 | - |
dc.subject | Irrigacion | es_ES |
dc.subject | Diseño De Agujas | es_ES |
dc.subject | Debris | es_ES |
dc.title | Eficacia de diferentes tipos de aguja de irrigación en la remoción de debris en dientes Bovinos | es_ES |
dc.type | masterThesis | es_ES |
dc.ucuenca.paginacion | 48 páginas | es_ES |
dc.description.degree | Especialista en Endodoncia | es_ES |
dc.description.city | Cuenca | es_ES |
dc.ucuenca.id | 0104151543 | es_ES |
dc.ucuenca.idautor | 0105244487 | es_ES |
Appears in Collections: | Tesis Especializaciones |
This item is protected by original copyright |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|