Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/26940
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorSoria Parra, Manuel Elías-
dc.contributor.authorMejìa Gutièrrez, Javier Esteban-
dc.date.accessioned2017-03-06T23:15:24Z-
dc.date.available2017-03-06T23:15:24Z-
dc.date.issued2017-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/26940-
dc.descriptionEl objetivo de esta investigación fue evaluar la calidad y la congelabilidad del semen obtenido mediante Vagina Artificial (VA) y Electroeyaculador (EE) en ganado biotipo criollo. El material seminal fue colectado de tres toros biotipo criollo, utilizando VA modelo IMV (VA T1=30) y Electroeyaculador electrónico portátil marca Standard Precisión Electronics®, que tras realizar el masaje tras-rectal para facilitar la excitación del animal, se introdujo el dispositivo que presenta un ciclo que va de 0 MA dejando entre ellas pausas de 2 segundos de descanso y se van elevando gradualmente hasta 150 MA promedio hasta conseguir la erección y posterior eyaculación (EE T2=30). Se procesó con diluyente AndroMed® ajustando a dosis inseminante de 20 x 106 y se sometió a un tiempo de equilibrio de 2 horas a 5oC. Se empajueló en pajillas de 0,25 ml y se sometió a vapores de nitrógeno líquido por 10 minutos y luego dejándolas caer para lograr una temperatura de -196oC. A los 30 días se descongeló para evaluar mediante microscopia óptica, calidad seminal Motilidad Masal (MM), Motilidad Individual Progresiva (MIP), Vitalidad Espermática (VE), Anormalidades, test de HOST y mediante el sistema CASA se evaluó motilidad total (TM), progresiva (IPM), local (LM) y espermatozoides inmóviles (IS). Se usó un diseño completamente al azar (DCA) y los resultados fueron analizados con el programa estadístico SPSS versión 22.0, posteriormente fueron sometidos a análisis donde la Media y Error estándar de las variables de calidad espermática precongelación comprobó la existencia de diferencias estadísticas (P0,05) en Concentración, MM, MIP y AT, atribuyendo eficacia al método de VA y las variables de calidad espermática post-congelación evidenció la existencia de diferencias estadísticas (P0,05) en AC y test de HOST, en la cual demuestra garantía en la utilización del método con VA. Con el sistema CASA no se encontró diferencias estadísticas (P<0.05) entre métodos de colecta en ningún parámetro. En conclusión, la utilización de vagina artificial como método de colecta de semen de bovino biotipo criollo obtenido por VA presenta mejores parámetros de calidad pre y post congelación que el semen que es colectado con electro EE.es_ES
dc.description.abstractThe objective of this research was to evaluate the quality and the freezing of semen obtained by Artificial Vagina (VA) and Electroeyaculator (EE) in creole biotype cattle. The seminal material was collected from three biotype creole bulls, using VA model IMV (VA T1 = 30) and Portable electronic Electroeyaculador brand Precision Electronics®, which after performing the rectal massage to facilitate the excitation of the animal, the device was introduced which presents a cycle which goes from 0 MA leaving between pauses of 2 seconds of rest and gradually rising to 150 MA rising to achieve erection and subsequent ejaculation (EE T2 = 30). It was processed with AndroMed® diluent adjusting at an inseminating dose of 20 x 106 and subjected to an equilibrium time of 2 hours at 5 ° C. It was soaked in 0.25 ml straws and subjected to liquid nitrogen vapors for 10 minutes and then dropped to a temperature of -196ºC. At 30 days, it was thawed to evaluate by electronic microscopy, seminal quality Motile Mass (MM), Progressive Individual Motility (MIP), Sperm Vitality (VE), Abnormalities, HOST test and by CASA system, quality total motile (TM), progressive (MPI), local (LM) and immotile spermatozoa (IS). A completely randomized design (DCA) was used and the results were analyzed with the statistical program SPSS version 22.0, later they were subjected to analysis where the mean and standard error of the variables of sperm quality pre-freezing verified the existence of statistical differences (P< 0.05) in Concentration, MM, MIP and AT, attributing efficacy to the VA method and post-freezing sperm quality variables evidenced the existence of statistical differences (P<0.05) in CA and HOST test, in the Which demonstrates the efficacy of the VA method. With the CASA system no statistical differences (P< 0.05) were found between collection methods in any parameter. In conclusion, the use of artificial vagina as a method of collecting semen from bovine biotype creole obtained by VA presents better pre and post freeze quality parameters than the semen that is collected with electro EE.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTM4A;111-
dc.subjectSemen De Toroes_ES
dc.subjectVagina Artificial- Toro Criolloes_ES
dc.subjectElectroeyaculador En Toro Criolloes_ES
dc.subjectGanado Criolloes_ES
dc.subjectMaestria En Reproduccion Animales_ES
dc.titleEvaluación pre y post congelación del semen obtenido con vagina artificial y electroeyaculador en el ganado criolloes_ES
dc.typemasterThesises_ES
dc.ucuenca.paginacion57 páginases_ES
dc.description.degreeMagìster en Reproducciòn Animales_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id1801620186es_ES
dc.ucuenca.idautor0103907663es_ES
dc.ucuenca.typesenescyt0es_ES
Appears in Collections:Tesis Maestrías

Files in This Item:
File Description SizeFormat 
Tesis.pdfPDF1.06 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00