Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/26112
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorDonoso Moscoso, Silvana Patricia-
dc.contributor.authorGarcía Moscoso, María Fernanda-
dc.contributor.authorMarca Sinchi, Marina Brígida-
dc.date.accessioned2016-12-01T16:28:20Z-
dc.date.available2016-12-01T16:28:20Z-
dc.date.issued2016-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/26112-
dc.descriptionEn el presente estudio se evaluó la eficiencia del proceso de potabilización de agua potable de “Patamarca-San Andrés” mediante la medición de parámetros físico-químicos y microbiológicos a lo largo del proceso. Este estudio fue de tipo cuantitativo, analítico, no experimental descriptivo de corte transversal. Las muestras analíticas fueron tomadas de puntos de control: desarenador, sedimentador, filtros, y unidad de desinfección. Se realizó en total 14 muestreos. Los parámetros evaluados fueron: físicos (pH, color, turbidez, sólidos totales disueltos), químicos (nitratos nitritos, cloro residual) y microbiológicos (coliformes totales y fecales). La eficiencia fue evaluada en las etapas de sedimentación, filtración y desinfección, para conocer el grado de remoción en cada etapa. Además se verificó si el agua tratada cumple con lo establecido en la Norma INEN 1108:2014. Los resultados generales se presentaron usando estadística descriptiva y gráficas de cajas y bigotes. Para el análisis de resultados se realizaron comparaciones entre el agua entrante y saliente de cada etapa del proceso de potabilización por medio de análisis de varianza (ANOVA) y pruebas de Scheffe (post-hoc ANOVA) para los parámetros físicos y microbiológicos. Para los parámetros químicos se aplicaron pruebas t de Student de dos colas, pues las mediciones se realizaron solamente en dos puntos de control (desarenador y desinfección). El cloro residual solo fue medido en el proceso de desinfección, por lo tanto no fue comparado con otros procesos. Se encontró que la eficiencia fue regular <70% en las etapas de sedimentación y filtración, y buena (70-80%) en la etapa de desinfecciónes_ES
dc.description.abstractThisstudyaimstoassesstheefficiency of thepurification of drinkingwater Patamarca-San Andrés bymeasuringphysical, chemical and microbiologicalparametersthroughouttheprocess. Thisstudyisdescriptive, quantitative, analytical and non-experimental cross- sectional. Theanalyticalsamplesweretakentreatmentfromcheckpointprocess: Desarenador (rawwater), Sedimentation (settled wáter), Filtration (filtered wáter) y disinfectionunit (treatedwater) . 14 sampleswereanalyzed. Theevaluatedparameters are: Physical (pH, color, turbidez, total disolved solids), chemical( nitrates, nitrites, residual chlorine) and microbiological ( total and fecal coliforms). Theefficiencywasevaluated in stages of sedimentation, filtration and disinfectingtoknowthedegree of removal at eachstage. In additionverifiediftreatedwatermeetstherequirements standard INEN 1108:2014. Theoverallresultswerepresentedusingdescriptivestatistics and box graphic and whiskergraphic. Fortheanalysis, results in each point the water treatment (desarenador, sedimentation, filtration and disinfection) was comparisons incoming water and outgoing water, throughvariance analysis (ANOVA) and Scheffé's method (post-hoc ANOVA) for physical and microbiological parameters analyzed. For analysis of chemical parameters was used Student's t-testthetwotailed test becausethemeasurements was only in two points the water treatment (desarenador and disinfection). The chlorine, free was measure in the disinfection process, consequently it wasn´t compare with other process. Toevaluatetheefficiency in stages of processpurification: sedimentation, filtration and disinfectionisfoundthattheefficiencywas regular < 70 % in stages of sedimentation and filtration and good (70-80%) onthestagedisinfection.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTBQ;669-
dc.subjectAgua Potablees_ES
dc.subjectBarrio Patamarcaes_ES
dc.subjectPotabilizaciones_ES
dc.titleEvaluación de la eficiencia del proceso de potabilización de agua de la planta Patamarca-San Andréses_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion78 páginases_ES
dc.description.degreeBioquímico Farmacéuticoes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102590569es_ES
dc.ucuenca.idautor0104551544es_ES
dc.ucuenca.idautor0105832596es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
trabajotitulación.pdf.pdftexto completo2.4 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00