Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/24033
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBravo Calderón, Manuel Estuardo-
dc.contributor.authorPinos Luzuriaga, Adrián Genaro-
dc.date.accessioned2016-03-23T15:54:49Z-
dc.date.available2016-03-23T15:54:49Z-
dc.date.issued2015-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/24033-
dc.descriptionEn la actualidad el uso de herramientas más sofisticadas en ortodoncia como son los programas de computadora y los modelos de estudio digitales, ha brindado mayores facilidades en el diagnóstico, planificación de un tratamiento y la fabricación de aparatología; cambiando la forma tradicional de medirlos, además de eliminar las desventajas que representa el almacenamiento físico de los mismos. El objetivo de este estudio fue comparar el grado de exactitud y fiabilidad del índice de Bolton y sus mediciones correspondientes entre los métodos manual y digital de modelos de estudio. El trabajo incluyó 50 modelos de estudio de pacientes del postgrado de ortodoncia de la Universidad de Cuenca, los cuales para la medición manual (estándar dorado) se empleó un calibrador digital tipo Vernier Mitutoyo de 0.01mm de precisión. Para el método digital se empleó un escáner de Laser óptico Optical RevEng y para las mediciones un programa de diagnóstico ortodóntico Nemocast 3D. La reproducibilidad entre los métodos se calculó a través de la prueba t de Student, su fiabilidad mediante el coeficiente de correlación de Pearson’s. El nivel de significancia estadística se estableció en 0.05. Resultados: Todos los resultados presentaron una excelente correlación entre ambos métodos, la prueba t indicó que existen diferencias significativas entre ambos métodos a excepción de la suma anterior inferior y el Bolton anterior. Conclusión: A pesar de que la reproducibilidad de ambos métodos mostró en su mayoría diferencias estadísticamente significativas, la precisión, exactitud y fiabilidad de los dos métodos fue alta y sus diferencias clínicamente irrelevanteses_ES
dc.description.abstractActually the use of more sophisticated tools in orthodontics such as digital software and digital studio models, has provided greater facility for the diagnosis, treatment planning and manufacture of appliances; changing the traditional approach to measurement, and eliminate the disadvantages that represents the physical storage. The aim of this study was to compare the accuracy and reliability of Bolton index and corresponding measurements between manual and digital methods of study models. The study included 50 patient study models of orthodontic postgraduate of the University of Cuenca, whereby for the manual measuring (gold standard) was employed a digital Vernier caliper Mitutoyo with 0.01mm accuracy. For digital method was used an optical laser scanner Optical RevEng and the measurements with an orthodontic software Nemocast 3D. The reproducibility of both methods was calculated by Student's t test, and reliability by Pearson's correlation coefficient. The statistical significance level was set at 0.05. Results: All results showed excellent correlation of both methods, the t test indicated that there are significant differences between the two methods except anteroinferior sum and anterior Bolton. Conclusion: Although the reproducibility of both methods showed mostly statistically significant differences; precision, accuracy and reliability of the two methods was high and clinically irrelevantes_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesODONOR;10-
dc.subjectModelo Digitales_ES
dc.subjectModelo De Estudioes_ES
dc.subjectIndice Boltones_ES
dc.subjectPrecisiones_ES
dc.subjectFiabilidades_ES
dc.titleDiagnóstico de modelos de yeso vs digitales: exactitud y fiabilidad en la comparación del análisis de bolton y sus mediciones correspondienteses_ES
dc.typemasterThesises_ES
dc.ucuenca.paginacion69 páginases_ES
dc.description.degreeEspecialista en Ortodonciaes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102137406es_ES
dc.ucuenca.idautor0105242580es_ES
Appears in Collections:Tesis Especializaciones

Files in This Item:
File Description SizeFormat 
tesis.pdftexto completo2.07 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00