Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/23058
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorArmas Novoa, Rolando-
dc.contributor.authorGonzález Avila, María Fernanda-
dc.contributor.authorPesántez Guaraca, Orlando Octavio-
dc.date.accessioned2015-11-06T17:29:22Z-
dc.date.available2015-11-06T17:29:22Z-
dc.date.issued2015-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/23058-
dc.descriptionPara el estudio de la estabilidad del talud aguas abajo de la presa Chojampe 2, bajo el estado de carga “operación”, se requiere un análisis en tensiones efectivas y, por ende, conocer las envolventes consolidada drenada, CD, de los suelos previamente saturados y compactados, del material de la cortina. Estas envolventes efectivas, pueden ser obtenidas mediante ensayos triaxiales consolidado-drenado o consolidado-no drenado, con medición de la presión de poro. La selección de uno u otro ensayo está en función del tiempo de ejecución de los mismos. Sin embargo, las envolventes efectivas obtenidas por ambos caminos no resultan iguales, por lo que se realiza un análisis comparativo de dichas envolventes. Los ensayos para realizar este estudio fueron proporcionados por el PROMAS, encargados del estudio y diseño del proyecto PACALORI. Las envolventes consolidadas drenadas fueron obtenidas mediante el método analítico (p’ vs q’), el cual nos brinda mayor precisión en los resultados y se concluye de los mismos, que la envolvente consolidada drenada, CD, obtenida mediante el ensayo triaxial Consolidado Drenado, es mayor que la envolvente Consolidada-Drenada, CD, obtenida mediante el ensayo Consolidado-No Drenado,CU, con medición de la presión de poro. Por lo tanto, se puede aplicar en el analisis de estabilidad, los resultados de la envolvente Consolidada Drenada, obtenida mediante el ensayo Consolidado No Drenado, con medición de presión de poro, ya que se reduce el tiempo de investigación de los materiales de préstamo y se está de lado seguro.es_ES
dc.description.abstractFor the stability study of the slope downstream of the Chojampe 2 dam, under the “operation” charge state, an analysis in effective stresses is required and, therefore, to know the envelopes consolidated drained, CD, of the soils previously saturated and compacted of the material of the curtain. These effective envelopes, can be obtained through the triaxial tests consolidated-drained or consolidated-undrained whit measure of the pore pressure. The choice of one or another test is in function of time of execution of the same. However, the effective envelopes obtained by both paths are not equal, so that a comparative analysis of said envelopes is performed. The tests for this study was provided by the PROMAS, responsible for the study and design the PACALORI project. The enveloped consolidated drained were obtained by analytical method (p´ vs q´) which offers more precision in the result and it concludes thereof, that the envelope consolidated-drained,CD,obtained by the triaxial test Consolidated Drained, It is greater than the Consolidated-Drained, CD envelope, obtained by Consolidated-undrained, CU, test with pore pressure measurement. Therefore, it can be applied to the stability analysis, the results of the Consolidated Drained envelope obtained by the Consolidated undrained test with pore pressure measurement, since it reduces time of investigation of the materials of loan and it is on the safe part.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTI;1015-
dc.subjectPresa Chojampees_ES
dc.subjectProvincia De Los Rioses_ES
dc.subjectEnsayos Triaxialeses_ES
dc.subjectConsolidado Drenadoes_ES
dc.subjectPacalories_ES
dc.titleEstudio comparativo entre las envolventes efectivas obtenidas con ensayos triaxiales consolidado drenado y consolidado-no drenado, con medición de presión de poro, en suelos compactados saturados de la presa Chojampe 2 de la provincia de Los Ríoses_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion129 páginases_ES
dc.description.degreeIngeniero Civiles_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0150697562es_ES
dc.ucuenca.idautor0104850508es_ES
dc.ucuenca.idautor0105604680es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Tesis.pdftexto completo29.12 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00