dc.descriptionLa presente tesis surge de la necesidad de utilizar el Equipo MilkoScan FT1 para realizar el análisis de leche cruda, como medida de control de calidad. Se trata de un equipo fabricado basándose en la tecnología del analizador de FTIR del MilkoScan FT120 de FOSS. El estudio se realizó en la Empresa de Lácteos San Antonio ubicada en el Parque Industrial de la Ciudad de Cuenca. El objetivo del proyecto fue calibrar y validar el equipo MilkoScan FT1 en los análisis de materia grasa, sólidos totales, sólidos no grasos y densidad relativa a 20ºC en leche cruda. Se utilizaron 80 muestras de leche cruda para la calibración. Para la regresión se usó el modelo de cuadrados mínimos parciales, obteniéndose un coeficiente de correlación (r) de 0.999 y un error estándar de predicción (EEP) de 0.009 para materia grasa; r de 0.996 y EEP de 0.147 para sólidos totales; r de 0.990 y EEP de 0.061 para sólidos no grasos; r de 0.993 y EEP de 0.633 para densidad relativa a 20ºC. En la validación se analizaron 80 muestras de leche cruda. La validación demostró que el método analítico empleado era lineal, preciso, exacto, sensible, robusto en el intervalo de concentraciones estudiadas. Tanto el proceso de validación como el desarrollo de procedimientos analíticos, se realizaron con el fin de cumplir con los requisitos técnicos señalados en la Norma ISO/IEC: 17025 para la acreditación del Laboratorio de Bromatología.es_ES
dc.description.abstractThis thesis arises from the need to use the equipment MilkoScan FT1 for analysis of raw milk, as a measure of quality control. It is a manufactured equipment technology based on FTIR analyzer from FOSS MilkoScan FT120. The study was conducted in San Antonio Dairy Company located in the Industrial Park of the City of Cuenca. The project objective was to calibrate and validate the equipment MilkoScan FT1 in analyzes of fat, total solids, nonfat solids and specific gravity at 20 ° C in raw milk. For calibration were used 80 raw milk samples. For the regression was used the partial least squares model, obtaining a correlation coefficient (r) of 0.999 and a standard error of prediction (EEP) to fat 0.009; a r of 0.996 and 0.147 of EEP to total solids; a r of 0.990 and 0.061 of EEP to non-fat solids; r of 0.993 and 0.633 EEP to relative density at 20 ° C. In the validation were analyzed 80 raw milk samples. The validation showed that the analytical method used was linear, precise, accurate, sensitive, robust in the concentration range studied. Both the validation process and the development of analytical procedures were performed in order to meet the technical requirements specified in ISO / IEC 17025 accreditation for Food Science Laboratory.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTBQ;637-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/-
dc.subjectCalibraciones_ES
dc.subjectBioquimicaes_ES
dc.subjectLeche Crudaes_ES
dc.subjectIndustria Lacteaes_ES
dc.subjectParametros Fisicoquimicoses_ES
dc.titleCalibración y validación del equipo milkoscan FT1 para la determinación de parámetros fisicoquímicos en leche cruda en la Industria de Lácteos San Antonio C.A.es_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion140 páginases_ES
dc.description.degreeBioquímico Farmacéuticoes_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0101613255es_ES
dc.ucuenca.idautor0302202544es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
TESIS.pdftexto completo3.16 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00