Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/21387
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJordán Villamar, Carlos-
dc.contributor.authorValderrama Saltos, Ismael-
dc.contributor.authorUniversidad de Cuenca-
dc.contributor.authorDirección de Investigación de la Universidad de Cuenca-
dc.contributor.authorDIUC-
dc.date.accessioned2015-03-09T12:58:40Z-
dc.date.available2015-03-09T12:58:40Z-
dc.date.issued2014-
dc.identifier.issn1390-6143-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/21387-
dc.descriptionEn este trabajo se aborda la aplicación de SPEA2, un método para optimización multiobjetivo, al cálculo de un esquema de dosificación para el tratamiento quimioterapéutico de una masa tumoral; entiéndase por esquema de dosificación la especificación del o de los agentes cito-tóxicos, sus dosis y tiempos en que deben administrarse. El problema de optimización aquí resuelto es uno multiobjetivo, pues el esquema de dosificación a calcularse debe minimizar no solo el tamaño del tumor, sino también la toxicidad remanente al término del tratamiento, su costo, etc. El SPEA2 es un algoritmo genético que aplica el criterio de Pareto; por lo tanto, lo que calcula es una aproximación a la frontera de Pareto, soluciones de entre las cuales el usuario puede escoger la “mejor”. En el proceso de esta investigación se construyó SoT-Q, una herramienta de software que consiste de dos módulos principales: un optimizador para calcular los esquemas de dosificación óptimos, y un simulador para aplicar dichos esquemas a un paciente (simulado) con masa tumoral; el funcionamiento del simulador se basa en un modelo fármaco-dinámico que representa el tumor. El programa SoT-Q podría en el futuro -una vez extensamente probado y depurado- asistir a médicos oncólogos en la toma de decisiones respecto a tratamientos quimioterapéuticos; o podría servir también como ayuda pedagógica en el entrenamiento de nuevos profesionales de la salud. Los resultados obtenidos fueron muy buenos; en todos los casos de prueba utilizados se logró reducir de manera significativa tanto el tamaño del tumor como la toxicidad remanente al término del tratamiento; en algunos casos la reducción fue de tres órdenes de magnitud.es_ES
dc.description.abstractThis paper presents the application of SPEA2 to calculate optimal dosage schemes for the chemotherapeutic treatments of tumors, where such schemes consists in the specification of several cytotoxic agents, its frequencies and doses to be administered. In this optimization problem, the calculated schedules should optimize more than one objective at the same time: not only tumor size but also the toxicity that remains after the treatment, cost, etc. SPEA2 is a genetic algorithm that applies the Pareto optimality criterion to calculate an approximation to the Pareto frontier, from which the user can choose the "best" or more appropriate solution. In this work a software tool was developed: SoT-Q. It has two main modules: an optimizer that calculates optimal dosage schemes and a simulator that applies these schedules to a simulated patient with a tumor; the functioning of the simulator is based on a pharmacodynamic model to represent the tumor. In the future, once SoT-Q is extensively tested and debugged, this computer program could assist oncologists in decision making about chemotherapy treatments; it could also serve as a teaching aid in training new health professionals. Results obtained using this tool were very good; in all test cases, both tumor size and residual toxicity at the end of treatment were reduced significantly; even more, in some examples the reduction was of three orders of magnitude.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Cuencaes_ES
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/-
dc.subjectCanceres_ES
dc.subjectQuimioterapiaes_ES
dc.subjectOptimizacion Multiobjetivoes_ES
dc.subjectAlgoritmos Geneticoses_ES
dc.subjectSpea2es_ES
dc.titleAplicación de SPEA2 al cálculo de esquemas de dosificación para el tratamiento quimioterapéutico del cánceres_ES
dc.title.alternativeMaskana. Revista Científicaes_ES
dc.typeArticlees_ES
dc.ucuenca.paginacionPáginas 69-83es_ES
dc.description.cityCuencaes_ES
dc.description.numberSequenceVolumen 5 (2014)es_ES
Appears in Collections:Volumen 5 No. especial (2014) - TIC.EC: Congreso Ecuatoriano de Tecnologías de la Información y Comunicaciones

Files in This Item:
File Description SizeFormat 
TIC.EC_07_Jordán Villamar & Valderrama Saltos.pdftexto completo413.46 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00