Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/21361
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Darío Rojas, Rubén | - |
dc.contributor.author | Universidad de Cuenca | - |
dc.contributor.author | Dirección de Investigación de la Universidad de Cuenca | - |
dc.contributor.author | DIUC | - |
dc.date.accessioned | 2015-03-06T17:47:23Z | - |
dc.date.available | 2015-03-06T17:47:23Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1390-6143 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/21361 | - |
dc.description | Este artículo propone una nueva estrategia de control basada en medidas continuas de glucosa y un controlador por modo deslizante que se habitúa (HSMC). El HSMC es desarrollado, combinando la ley de control por modo deslizante y los principios de control por habituación. El HSMC aplicado a la regulación de glucosa sanguínea en la unidad de cuidados intensivos, incluye tanto entrada de glucosa, como de infusión de insulina intravasculares a fin de proveer el suministro de nutrición y mejorar el rechazo a la perturbación. El estudio basado en simulaciones (in silico), usando un modelo fisiológico de la dinámica glucosa-insulina, muestra que la estrategia de control propuesta funciona apropiadamente. Finalmente, se compara el desempeño del controlador propuesto con respecto a un controlador PID estándar. | es_ES |
dc.description.abstract | This article proposes a new strategy of control based on continue measurements of glucose and a habituating sliding mode controller (HSMC). The HSMC is developed combining the sliding mode control law and the principles of habituating control. The HSMC applied to the regulation of blood glucose in the intensive care unit, includes both intravascular glucose and insulin infusion inputs to provide the nutrition supply and to improve the rejection to disturbances. The simulation based study (in silico), using a physiological model of the dynamic glucose-insulin, shows that proposed control strategy works properly. Finally, the performance of the proposed controller and a standard PID controller are compared. | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad de Cuenca | es_ES |
dc.rights | openAccess | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | - |
dc.subject | Control | es_ES |
dc.subject | Control Modo Deslizante | es_ES |
dc.subject | Regulacion De Glucosa Sanguinea | es_ES |
dc.subject | Servicios De Salud | es_ES |
dc.subject | Centro De Gestion | es_ES |
dc.subject | Glucosa Sanguinea | es_ES |
dc.title | Control HSMC para regulación de glucosa sanguínea | es_ES |
dc.title.alternative | Maskana. Revista Científica | es_ES |
dc.type | Article | es_ES |
dc.ucuenca.paginacion | Páginas 12-131 | es_ES |
dc.description.city | Cuenca | es_ES |
dc.description.numberSequence | Volumen 5 (2014) | es_ES |
Appears in Collections: | Volumen 5 No. especial (2014) - MATCH'14: Congreso de Reconocimiento de Patrones, Control Inteligente y Comunicaciones |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MATCH'14_13_Rojas.pdf | texto completo | 396.74 kB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|