Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/21355
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Véliz, Bremnen | - |
dc.contributor.author | Huilcapi, Víctor | - |
dc.contributor.author | Cajo, Ricardo | - |
dc.contributor.author | Universidad de Cuenca | - |
dc.contributor.author | Dirección de Investigación de la Universidad de Cuenca | - |
dc.contributor.author | DIUC | - |
dc.date.accessioned | 2015-03-06T17:08:22Z | - |
dc.date.available | 2015-03-06T17:08:22Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1390-6143 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/21355 | - |
dc.description | Un estudio comparativo de la impedancia de un polímero tipo poliolefina termoplástica elastómera con un electrodo comercial gelificado universal ha sido hecho con el fin de determinar si el polímero puede ser usado como electrodo seco para la adquisición de señales cardiacas. Los resultados de la espectrometría de impedancia mostraron características muy parecidas y que ambos se comportan como dispositivos resistores, por ejemplo a 120 Hz el polímero registró una resistencia de 6,3 k y el electrodo comercial 7,2 k . Además, se obtuvo una relación lineal de corriente contra voltaje, determinando resistencias de 7 k y 8,2 k para el polímero y electrodo comercial gelificado respectivamente. Finalmente concluimos que es aplicable el uso de este polímero en electrodos secos. | es_ES |
dc.description.abstract | A comparative impedance study of a polymer type Thermoplastic Polyolefin Elastomer with a commercial universal gel electrode has been made in order to know whether the polymer can be used as dry electrode for the acquisition of cardiac signals. The results of the impedance spectroscopy showed very similar characteristics and that both devices behave as resistors. For instance, at 120 Hz the polymer measured a resistance of 6,3 k and the commercial gel electrode 7,2 k . Further, it was getting a linear relation of current versus voltage, determining resistances of 7 k and 8,2 k for the polymer and commercial gelled electrode respectively. Finally we have concluded that the polymer is applicable to construct dry electrodes. | es_ES |
dc.format | application/pdf | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Universidad de Cuenca | es_ES |
dc.rights | openAccess | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | - |
dc.subject | Electrodos | es_ES |
dc.subject | Polimeros | es_ES |
dc.subject | Poliolefina Termoplastica Elastomera | es_ES |
dc.subject | Electrocardiograma | es_ES |
dc.subject | Espectroscopia De Impedancia | es_ES |
dc.title | Caracterización espectroscópica de impedancia de polímeros para el uso en electrodos de electrocardiogramas | es_ES |
dc.title.alternative | Maskana. Revista Científica | es_ES |
dc.type | Article | es_ES |
dc.ucuenca.paginacion | Páginas 103-109 | es_ES |
dc.description.city | Cuenca | es_ES |
dc.description.numberSequence | Volumen 5 (2014) | es_ES |
Appears in Collections: | Volumen 5 No. especial (2014) - MATCH'14: Congreso de Reconocimiento de Patrones, Control Inteligente y Comunicaciones |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
MATCH'14_11_Véliz et al.pdf | texto completo | 476.7 kB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|